Harmonization of Quantitative Values in Bone SPECT/CT for Medication-Related Osteonecrosis of the Jaw

The increased use of antiresorptive and antiangiogenic agents in patients with osteoporosis and cancer is closely linked to decreases in quality of life attributable to medication-related osteonecrosis of the jaw (MRONJ), emphasizing the need for accurate diagnosis. Recent advances in quantitative SPECT/CT (Q-SPECT/CT) using bone scintigraphy have enhanced its utility for the early detection and staging of MRONJ. However, the lack of harmonization criteria for SUVs across various scanners hampers multicenter studies. <b>Methods:</b> To address this issue, we conducted a multicenter phantom study to identify harmonization criteria for Q-SPECT/CT in MRONJ and evaluate a software-based harmonization approach. A custom-made brain tumor phantom with 6 hot spheres was filled with a <sup>99m</sup>Tc-hydroxymethylene diphosphonate solution (17.5 kBq/mL in the background and 70 kBq/mL in the hot spheres, yielding a hot sphere-to-background ratio of 4). SPECT/CT was performed at 7 institutions using 8 scanners in accordance with clinical protocols. A cylindric phantom was used to calculate the becquerel calibration factor, and a tool for analyzing region of interest and volume of interest was used for SUV conversion, analysis, and harmonization. The harmonization criterion was the median SUV<sub>max</sub> ± 30% across scanners. If the SUV<sub>max</sub> exceeded this range, then a 3-dimensional gaussian filter was applied. <b>Results:</b> The SUV<sub>mean</sub> in the background region remained within 0.95-1.05 (relative to the theoretic value of 1.00) both before and after harmonization, with minimal interscanner differences. Conversely, for the hot spheres, the maximum coefficients of variation for SUV<sub>max</sub>, SUV<sub>peak</sub>, and SUV<sub>mean</sub> improved from 122%, 68%, and 71%, respectively, before harmonization to 48%, 35%, and 37%, respectively, after harmonization. <b>Conclusion:</b> We identified a harmonization criterion for Q-SPECT/CT in MRONJ and demonstrated that our software-based approach effectively reduces interscanner variability without compromising clinical image quality or requiring additional image reconstruction, supporting its utility in multicenter clinical studies.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Medicine Technology
Published
2025-08-26
DOI
https://doi.org/10.2967/jnmt.125.269873
Citations
2
Primary Topic
Bone health and treatments
Type
article
Field-Weighted Citation Impact
2.09
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonization of Quantitative Values in Bone SPECT/CT for Medication-Related Osteonecrosis of the Jaw

Naoya Hayashi, Takashi Norikane, Yukito Maeda, Hiromitsu Daisaki et al.
2 citations
Journal of Nuclear Medicine Technology
Bone health and treatments
2.09
article

Harmonization of Quantitative Values in Bone SPECT/CT for Medication-Related Osteonecrosis of the Jaw

Naoya Hayashi, Takashi Norikane, Yukito Maeda, Hiromitsu Daisaki, Yoshiki Owaki, Kimiteru Ito, Tatsuya Tsuchitani, Kazuhiro Kitajima, Hayato Kaida, Yu Iwabuchi, Masakazu Tsujimoto, Issei Kuromori, N Ueno, Yoshitaka Inui
article en
2 citations

Abstract

The increased use of antiresorptive and antiangiogenic agents in patients with osteoporosis and cancer is closely linked to decreases in quality of life attributable to medication-related osteonecrosis of the jaw (MRONJ), emphasizing the need for accurate diagnosis. Recent advances in quantitative SPECT/CT (Q-SPECT/CT) using bone scintigraphy have enhanced its utility for the early detection and staging of MRONJ. However, the lack of harmonization criteria for SUVs across various scanners hampers multicenter studies. <b>Methods:</b> To address this issue, we conducted a multicenter phantom study to identify harmonization criteria for Q-SPECT/CT in MRONJ and evaluate a software-based harmonization approach. A custom-made brain tumor phantom with 6 hot spheres was filled with a <sup>99m</sup>Tc-hydroxymethylene diphosphonate solution (17.5 kBq/mL in the background and 70 kBq/mL in the hot spheres, yielding a hot sphere-to-background ratio of 4). SPECT/CT was performed at 7 institutions using 8 scanners in accordance with clinical protocols. A cylindric phantom was used to calculate the becquerel calibration factor, and a tool for analyzing region of interest and volume of interest was used for SUV conversion, analysis, and harmonization. The harmonization criterion was the median SUV<sub>max</sub> ± 30% across scanners. If the SUV<sub>max</sub> exceeded this range, then a 3-dimensional gaussian filter was applied. <b>Results:</b> The SUV<sub>mean</sub> in the background region remained within 0.95-1.05 (relative to the theoretic value of 1.00) both before and after harmonization, with minimal interscanner differences. Conversely, for the hot spheres, the maximum coefficients of variation for SUV<sub>max</sub>, SUV<sub>peak</sub>, and SUV<sub>mean</sub> improved from 122%, 68%, and 71%, respectively, before harmonization to 48%, 35%, and 37%, respectively, after harmonization. <b>Conclusion:</b> We identified a harmonization criterion for Q-SPECT/CT in MRONJ and demonstrated that our software-based approach effectively reduces interscanner variability without compromising clinical image quality or requiring additional image reconstruction, supporting its utility in multicenter clinical studies.

Journal of Nuclear Medicine TechnologyVol. 53(4)
Hyogo Medical University (JP), Keio University (JP), National Cancer Centre Japan (JP), Kochi Medical School Hospital (JP), National Cancer Center (US), Kindai University Hospital (JP), Fujita Health University Hospital (JP), Kagawa University Hospital (JP), National Cancer Center Hospital East (JP), Tokyo National Hospital (JP), Gunma Prefectural College of Health Sciences (JP), Hyogo University (JP), Kindai University (JP)
Zero hunger
Openalex Percentile: Top 11%
Bone health and treatments
2.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.