Metallosis in Total Hip Arthroplasty Using Modular Dual Mobility Implant: A Case Report
Case A patient that underwent dual mobility liner placement presented at follow up with clinical history and imaging findings indicative of metallosis. This phenomenon with dual mobility implants is not well reported in the literature. Conclusion Although dual mobility implants allow for increased stability of the acetabular component, the benefits conferred should be weighed against the potential complications. Ensuring proper cup placement and adequate screw fixation can potentially mitigate the risk of metallosis in these cases.
Authors
- Himanshu Rao
- Christopher M. Ferguson
- Shaan Sadhwani (ORCID: https://orcid.org/0000-0002-5635-943X)
- Brian Omslaer
- Daniel H. Kim (ORCID: https://orcid.org/0009-0007-7624-2830)
Publication Details
- Journal
- Journal of the American Osteopathic Academy of Orthopedics
- Published
- 2025-08-22
- DOI
- https://doi.org/10.70709/bfik4ioe4z
- Primary Topic
- Orthopaedic implants and arthroplasty
- Type
- article
- Field-Weighted Citation Impact
- 0.00