Detection of Masquerade Attacks on Protection of Digital Substations Using Real-Time Measurements

Power substations play a critical role in maintaining efficient and stable electricity distribution within electrical grids by enabling switching operations, voltage transformation, and system protection. Digital substations commonly use the GOOSE protocol for rapid, reliable communication between protection relays during fault events. However, exploiting security vulnerabilities of the GOOSE protocol by masquerade attacks threatens the physical protection operations in digital substations. This paper presents a real-time verification method for detecting such attacks by utilizing measurements obtained locally by the relays, along with measurements exchanged via the protocol. The method uses phase angle and Root Mean Square (RMS) value comparisons, and proposes voltage and current boundary rules to distinguish legitimate messages from forged ones. The proposed verification approach has been validated through a simulation model, incorporating realistic substation configurations and network delays across five use cases. The results highlight its effectiveness in strengthening the cybersecurity of protection operations in digital substations.

Authors

Publication Details

Published
2025-08-04
DOI
https://doi.org/10.1109/csr64739.2025.11130060
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Masquerade Attacks on Protection of Digital Substations Using Real-Time Measurements

Lenos Hadjidemetriou, Christos Laoudias, Mohamed Faisal Elrawy, Maria K. Michael
Smart Grid Security and Resilience
article

Detection of Masquerade Attacks on Protection of Digital Substations Using Real-Time Measurements

Lenos Hadjidemetriou, Christos Laoudias, Mohamed Faisal Elrawy, Maria K. Michael
article en

Abstract

Power substations play a critical role in maintaining efficient and stable electricity distribution within electrical grids by enabling switching operations, voltage transformation, and system protection. Digital substations commonly use the GOOSE protocol for rapid, reliable communication between protection relays during fault events. However, exploiting security vulnerabilities of the GOOSE protocol by masquerade attacks threatens the physical protection operations in digital substations. This paper presents a real-time verification method for detecting such attacks by utilizing measurements obtained locally by the relays, along with measurements exchanged via the protocol. The method uses phase angle and Root Mean Square (RMS) value comparisons, and proposes voltage and current boundary rules to distinguish legitimate messages from forged ones. The proposed verification approach has been validated through a simulation model, incorporating realistic substation configurations and network delays across five use cases. The results highlight its effectiveness in strengthening the cybersecurity of protection operations in digital substations.

Openalex Percentile: Top 73%
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detection of Masquerade Attacks on Protection of Digital Substations Using Real-Time Measurements — Lenos Hadjidemetriou, Christos Laoudias, et al. · (2025) | TGRS Research Map | TGRS