To Spray or To Sublimate: Considerations for the Matrix Application of Three Common Positive Ion Mode Matrices

Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) is a powerful tool for imaging lipids, proteins, <i>N</i>-glycans, metabolites, and drugs in situ. A key step in MALDI MSI is matrix deposition, which must balance the extraction of molecules from the surface of the tissue without inducing excessive analyte delocalization. Further, MALDI MSI spatial resolution is limited by the size of the matrix crystals formed during matrix deposition. Minimizing crystal size is paramount to obtaining detailed images and refined data. Sublimation has been shown to be a reliable method of depositing matrix while minimizing crystal size. Since sublimation does not use any solvents to deposit the matrix, it is also theorized to minimize analyte delocalization. However, these same solvents are thought to aid in analyte extraction, which may limit detection by sublimation. In this study, we compared crystal size, analyte delocalization, and signal intensity differences when using a commercial automatic pneumatic sprayer and a sublimator for lipid imaging analyses. We tested three matrices: α-cyano-4-hydroxycinnamic acid (CHCA), 2,5-dihydroxyacetophenone (DHAP), and 2,5-dihydroxybenzoic acid (DHB) on mouse brain, heart, and kidney. Our results revealed that crystal size depended upon the matrix and whether the crystals formed on or off tissue. Our data also showed that only a subset of the lipid spectrum was susceptible to increased delocalization from spraying and decreased signal intensity from sublimation.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-08-26
DOI
https://doi.org/10.1021/acs.analchem.5c01767
Citations
4
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
3.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

To Spray or To Sublimate: Considerations for the Matrix Application of Three Common Positive Ion Mode Matrices

Alyson Black, Caitlin M. Tressler, Kristine Glunde, Alain Creissen et al.
4 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
3.03
article

To Spray or To Sublimate: Considerations for the Matrix Application of Three Common Positive Ion Mode Matrices

Alyson Black, Caitlin M. Tressler, Kristine Glunde, Alain Creissen, Tae‐Hun Hahm, Wanyue Wang, Cole C. Johnson, Dalton R. Brown, Ian Spears, Gabriella Lagdameo
article en
4 citations

Abstract

Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) is a powerful tool for imaging lipids, proteins, <i>N</i>-glycans, metabolites, and drugs in situ. A key step in MALDI MSI is matrix deposition, which must balance the extraction of molecules from the surface of the tissue without inducing excessive analyte delocalization. Further, MALDI MSI spatial resolution is limited by the size of the matrix crystals formed during matrix deposition. Minimizing crystal size is paramount to obtaining detailed images and refined data. Sublimation has been shown to be a reliable method of depositing matrix while minimizing crystal size. Since sublimation does not use any solvents to deposit the matrix, it is also theorized to minimize analyte delocalization. However, these same solvents are thought to aid in analyte extraction, which may limit detection by sublimation. In this study, we compared crystal size, analyte delocalization, and signal intensity differences when using a commercial automatic pneumatic sprayer and a sublimator for lipid imaging analyses. We tested three matrices: α-cyano-4-hydroxycinnamic acid (CHCA), 2,5-dihydroxyacetophenone (DHAP), and 2,5-dihydroxybenzoic acid (DHB) on mouse brain, heart, and kidney. Our results revealed that crystal size depended upon the matrix and whether the crystals formed on or off tissue. Our data also showed that only a subset of the lipid spectrum was susceptible to increased delocalization from spraying and decreased signal intensity from sublimation.

Analytical ChemistryVol. 97(35)
University of Maryland, Baltimore (US), Johns Hopkins University (US), Johns Hopkins Medicine (US), IONICS Mass Spectrometry (Canada) (CA), Clinical Tools, Inc. (US), Sidney Kimmel Comprehensive Cancer Center (US), Himax (Taiwan) (TW)
U.S. Department of Defense, NIH Office of the Director, National Institute of Neurological Disorders and Stroke
Openalex Percentile: Top 8%
Mass Spectrometry Techniques and Applications
3.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.