MGFormer: Super-Resolution Reconstruction of Retinal OCT Images Based on a Multi-Granularity Transformer

Optical coherence tomography (OCT) acquisitions often reduce lateral sampling density to shorten scan time and suppress motion artifacts, but this strategy degrades the signal-to-noise ratio and obscures fine retinal microstructures. To recover these details without hardware modifications, we propose MGFormer, a lightweight Transformer for OCT super-resolution (SR) that integrates a multi-granularity attention mechanism with tensor distillation. A feature-enhancing convolution first sharpens edges; stacked multi-granularity attention blocks then fuse coarse-to-fine context, while a row-wise top-k operator retains the most informative tokens and preserves their positional order. We trained and evaluated MGFormer on B-scans from the Duke SD-OCT dataset at 2×, 4×, and 8× scaling factors. Relative to seven recent CNN- and Transformer-based SR models, MGFormer achieves the highest quantitative fidelity; at 4× it reaches 34.39 dB PSNR and 0.8399 SSIM, surpassing SwinIR by +0.52 dB and +0.026 SSIM, and reduces LPIPS by 21.4%. Compared with the same backbone without tensor distillation, FLOPs drop from 289G to 233G (−19.4%), and per-B-scan latency at 4× falls from 166.43 ms to 98.17 ms (−41.01%); the model size remains compact (105.68 MB). A blinded reader study shows higher scores for boundary sharpness (4.2 ± 0.3), pathology discernibility (4.1 ± 0.3), and diagnostic confidence (4.3 ± 0.2), exceeding SwinIR by 0.3–0.5 points. These results suggest that MGFormer can provide fast, high-fidelity OCT SR suitable for routine clinical workflows.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2025-08-25
DOI
https://doi.org/10.3390/photonics12090850
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MGFormer: Super-Resolution Reconstruction of Retinal OCT Images Based on a Multi-Granularity Transformer

Yichao Si, Jingmin Luan, Jia Sun, Zhenhe Ma et al.
Photonics
Optical Coherence Tomography Applications
article

MGFormer: Super-Resolution Reconstruction of Retinal OCT Images Based on a Multi-Granularity Transformer

Yichao Si, Jingmin Luan, Jia Sun, Zhenhe Ma, Dongni Yang, Yutian Li, Yao Yu, Jian Liu, Z. Jiao, Zehao Wei
article en

Abstract

Optical coherence tomography (OCT) acquisitions often reduce lateral sampling density to shorten scan time and suppress motion artifacts, but this strategy degrades the signal-to-noise ratio and obscures fine retinal microstructures. To recover these details without hardware modifications, we propose MGFormer, a lightweight Transformer for OCT super-resolution (SR) that integrates a multi-granularity attention mechanism with tensor distillation. A feature-enhancing convolution first sharpens edges; stacked multi-granularity attention blocks then fuse coarse-to-fine context, while a row-wise top-k operator retains the most informative tokens and preserves their positional order. We trained and evaluated MGFormer on B-scans from the Duke SD-OCT dataset at 2×, 4×, and 8× scaling factors. Relative to seven recent CNN- and Transformer-based SR models, MGFormer achieves the highest quantitative fidelity; at 4× it reaches 34.39 dB PSNR and 0.8399 SSIM, surpassing SwinIR by +0.52 dB and +0.026 SSIM, and reduces LPIPS by 21.4%. Compared with the same backbone without tensor distillation, FLOPs drop from 289G to 233G (−19.4%), and per-B-scan latency at 4× falls from 166.43 ms to 98.17 ms (−41.01%); the model size remains compact (105.68 MB). A blinded reader study shows higher scores for boundary sharpness (4.2 ± 0.3), pathology discernibility (4.1 ± 0.3), and diagnostic confidence (4.3 ± 0.2), exceeding SwinIR by 0.3–0.5 points. These results suggest that MGFormer can provide fast, high-fidelity OCT SR suitable for routine clinical workflows.

PhotonicsVol. 12(9)
Northwestern Polytechnical University (CN), Jinan City People's Hospital (CN), Shandong First Medical University (CN), First Hospital of Qinhuangdao (CN), Northeastern University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 79%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.