Graphene-based LSPR sensors enable polarization-independent detection of CEA antigens

This study presents a biosensor based on cleaved graphene, compared with a graphene-gold nanoparticle structure, for detecting carcinoembryonic antigen (CEA), leveraging graphene's tunable resonance frequency and the structure's polarization-independent performance. This sensor consists of three layers: a gold substrate with a conductivity of 4.7 × 10<sup>7</sup>, a silicon dioxide (SiO<sub>2</sub>) dielectric layer with a permeability of 3.9, and a graphene layer with strategic cuts to increase absorption. The performance of the proposed structure has been measured by measuring its absorption around the 8.9 terahertz frequency band, which has reached absorption values ​​above 99.4-99.9% for the first structure and absorption above 99.6-100% for the second structure, which includes graphene plus gold nanoparticles, respectively. These high absorption rates make the sensor an excellent candidate for biosensing applications, especially for the detection of CEA in clinical samples. By testing the sensor with analytes containing CEA in concentrations of 1, 2, 3, 4, and 5 ng/ml, the refractive index values ​​were 1.3337, 1.33374, 1.3448, and 1.3485, respectively. When the analyte layer is placed on the three-band absorber structure, the peak shift is absorbed and allows the detection of the desired analyte. The second proposed structure showed significant sensitivity and achieved 4.3 THz / RIU at 1.3411 refractive index and 8.8483 THz frequency, LOD = 0.001 and FOM = 26. This high sensitivity is especially useful for detecting low concentrations of analyte. Such a sensor has a high potential to increase the detection of biomarkers. These findings highlight the potential of the sensor for CEA detection with high sensitivity.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-08-26
DOI
https://doi.org/10.1038/s41598-025-17108-9
Citations
5
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
4.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Graphene-based LSPR sensors enable polarization-independent detection of CEA antigens

Javad Javidan, Hamid Bahador, Yousef Rafighirani
5 citations
Scientific Reports
Advanced biosensing and bioanalysis techniques
4.03
article

Graphene-based LSPR sensors enable polarization-independent detection of CEA antigens

Javad Javidan, Hamid Bahador, Yousef Rafighirani
article en
5 citations

Abstract

This study presents a biosensor based on cleaved graphene, compared with a graphene-gold nanoparticle structure, for detecting carcinoembryonic antigen (CEA), leveraging graphene's tunable resonance frequency and the structure's polarization-independent performance. This sensor consists of three layers: a gold substrate with a conductivity of 4.7 × 10<sup>7</sup>, a silicon dioxide (SiO<sub>2</sub>) dielectric layer with a permeability of 3.9, and a graphene layer with strategic cuts to increase absorption. The performance of the proposed structure has been measured by measuring its absorption around the 8.9 terahertz frequency band, which has reached absorption values ​​above 99.4-99.9% for the first structure and absorption above 99.6-100% for the second structure, which includes graphene plus gold nanoparticles, respectively. These high absorption rates make the sensor an excellent candidate for biosensing applications, especially for the detection of CEA in clinical samples. By testing the sensor with analytes containing CEA in concentrations of 1, 2, 3, 4, and 5 ng/ml, the refractive index values ​​were 1.3337, 1.33374, 1.3448, and 1.3485, respectively. When the analyte layer is placed on the three-band absorber structure, the peak shift is absorbed and allows the detection of the desired analyte. The second proposed structure showed significant sensitivity and achieved 4.3 THz / RIU at 1.3411 refractive index and 8.8483 THz frequency, LOD = 0.001 and FOM = 26. This high sensitivity is especially useful for detecting low concentrations of analyte. Such a sensor has a high potential to increase the detection of biomarkers. These findings highlight the potential of the sensor for CEA detection with high sensitivity.

Scientific ReportsVol. 15(1)
University of Mohaghegh Ardabili (IR)
Affordable and clean energy
Openalex Percentile: Top 6%
Advanced biosensing and bioanalysis techniques
4.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Graphene-based LSPR sensors enable polarization-independent detection of CEA antigens — Javad Javidan, Hamid Bahador, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS