Quantification of HER2-low and ultra-low expression in breast cancer specimens by quantitative IHC and artificial intelligence

Recent results of clinical trials in antibody drug conjugate (ADC) therapies have significantly broadened treatment options for the HER2 low and ultra-low breast cancer patients. However, sensitive, accurate and quantitative evaluation of HER2 expression based on current immunohistochemistry (IHC) assays remains challenging, especially in low and ultra-low HER2 expression ranges. We developed a novel methodology for quantifying HER2 protein expression, targeting breast cancer cases in the HER2 IHC 0 and 1+ categories. We measured HER2 expression using quantitative IHC (qIHC) that enables precise and tunable HER2 detection across different expression levels as demonstrated in formalin-fixed paraffin-embedded cell lines. Additionally, we developed an AI-based interpretation of HercepTest™ mAb pharmDx (Dako Omnis) (HercepTest™ mAb) using qIHC measurements as the ground truth. Both methodologies allowed spatial resolution and visualization of low and ultra-low levels of HER2 expression across entire tissue sections to demonstrate and enable quantification of heterogeneity of HER2 expression. Serial sections of 82 formalin-fixed paraffin-embedded tissue blocks of invasive breast carcinoma with HER2 IHC scores 0 or 1+ were stained with H&E, HercepTest™ (mAb), qIHC and p63, then scanned and digitally aligned. Tumor areas were manually selected and reviewed by expert pathologists. HER2 expression was quantitatively evaluated based on the qIHC assay in each 128x128μm<sup>2</sup> area within tumor regions. We observed statistically significant differences in HER2 expression between IHC 0, 0 < IHC < 1+, and IHC 1+ groups, and a high degree of spatial heterogeneity of the HER2 expression levels within the same tissue, up to five-fold in some cases. We demonstrated high slide-level tumor region agreement of estimates of HER2 expression between the AI-based interpretation of HercepTest™ mAb and the qIHC ground truth with a Pearson correlation of 0.94, and R<sup>2</sup> of 0.87. The developed methodologies can be used to stratify HER2 low-expression patient groups, potentially improving the interpretation of IHC assays and maximizing therapeutic benefits. This method can be implemented in histology labs without requiring a specialized workflow.

Authors

Institutions

Publication Details

Journal
Journal of Pathology Informatics
Published
2025-08-26
DOI
https://doi.org/10.1016/j.jpi.2025.100513
Citations
4
Primary Topic
HER2/EGFR in Cancer Research
Type
article
Field-Weighted Citation Impact
4.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification of HER2-low and ultra-low expression in breast cancer specimens by quantitative IHC and artificial intelligence

Jens Mollerup, Sarit Aviel‐Ronen, Daniela Rabkin, Amir Ben‐Dor et al.
4 citations
Journal of Pathology Informatics
HER2/EGFR in Cancer Research
4.18
article

Quantification of HER2-low and ultra-low expression in breast cancer specimens by quantitative IHC and artificial intelligence

Jens Mollerup, Sarit Aviel‐Ronen, Daniela Rabkin, Amir Ben‐Dor, Gitte Nielsen, Itay Remer, Frederik Aidt, Kirsten Hoff, Lars Jacobsen, Karin Salomon, Elad Arbel, Anya Tsalenko, Oded Ben-David
article en
4 citations

Abstract

Recent results of clinical trials in antibody drug conjugate (ADC) therapies have significantly broadened treatment options for the HER2 low and ultra-low breast cancer patients. However, sensitive, accurate and quantitative evaluation of HER2 expression based on current immunohistochemistry (IHC) assays remains challenging, especially in low and ultra-low HER2 expression ranges. We developed a novel methodology for quantifying HER2 protein expression, targeting breast cancer cases in the HER2 IHC 0 and 1+ categories. We measured HER2 expression using quantitative IHC (qIHC) that enables precise and tunable HER2 detection across different expression levels as demonstrated in formalin-fixed paraffin-embedded cell lines. Additionally, we developed an AI-based interpretation of HercepTest™ mAb pharmDx (Dako Omnis) (HercepTest™ mAb) using qIHC measurements as the ground truth. Both methodologies allowed spatial resolution and visualization of low and ultra-low levels of HER2 expression across entire tissue sections to demonstrate and enable quantification of heterogeneity of HER2 expression. Serial sections of 82 formalin-fixed paraffin-embedded tissue blocks of invasive breast carcinoma with HER2 IHC scores 0 or 1+ were stained with H&E, HercepTest™ (mAb), qIHC and p63, then scanned and digitally aligned. Tumor areas were manually selected and reviewed by expert pathologists. HER2 expression was quantitatively evaluated based on the qIHC assay in each 128x128μm<sup>2</sup> area within tumor regions. We observed statistically significant differences in HER2 expression between IHC 0, 0 < IHC < 1+, and IHC 1+ groups, and a high degree of spatial heterogeneity of the HER2 expression levels within the same tissue, up to five-fold in some cases. We demonstrated high slide-level tumor region agreement of estimates of HER2 expression between the AI-based interpretation of HercepTest™ mAb and the qIHC ground truth with a Pearson correlation of 0.94, and R<sup>2</sup> of 0.87. The developed methodologies can be used to stratify HER2 low-expression patient groups, potentially improving the interpretation of IHC assays and maximizing therapeutic benefits. This method can be implemented in histology labs without requiring a specialized workflow.

Journal of Pathology InformaticsVol. 19
Agilent Technologies (United States) (US), Agilent Technologies (Denmark) (DK), Ariel University (IL)
Openalex Percentile: Top 5%
HER2/EGFR in Cancer Research
4.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.