Efficient removal of high concentrations of sulfate, chloride, and total hardness from industrial effluents using nanofiltration membrane technology

Sulfate ions, chloride ions, and water hardness represent significant challenges in the treatment of industrial effluents. In this study, a polyamide spiral-wound nanofiltration membrane was applied under various operating conditions to remove these contaminants. Removal performance for sulfate and chloride ions, total hardness reduction, electrical conductivity reduction, and water recovery was assessed, with pH, feed flow rate, and operating pressure selected as key process variables. The experimental results were analyzed using the Response Surface Methodology–Central Composite Design (RSM–CCD) approach, and a face-centered design was employed to determine the relationships between input variables and output responses. Process optimization identified the optimal operating conditions as 7 bar pressure, 10 L/min feed flow rate, and pH 4.62. Under these conditions, water recovery, sulfate ion removal, total hardness removal, chloride ion removal, and electrical conductivity reduction reached 29.9%, 99.4%, 97.7%, 80.9%, and 92.23%, respectively. Recovery rate increased with higher operating pressure and decreased with increased feed flow rate, with minimal dependence on pH. Sulfate removal was strongly dependent on pressure, showing a slight decrease at higher pH values, while total hardness removal followed a similar trend with weaker pH sensitivity. Chloride removal exhibited lower pressure dependence but increased with pH. Given the high contaminant removal efficiencies achieved without the use of chemical additives and with moderate energy consumption, the polyamide spiral-wound nanofiltration process is demonstrated to be an effective and sustainable method for treating industrial effluents.

Authors

Institutions

Publication Details

Journal
Discover Applied Sciences
Published
2025-08-26
DOI
https://doi.org/10.1007/s42452-025-07656-0
Citations
1
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
0.82
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficient removal of high concentrations of sulfate, chloride, and total hardness from industrial effluents using nanofiltration membrane technology

Vahid Javanbakht, Mohsen Teimouri
1 citations
Discover Applied Sciences
Membrane Separation Technologies
0.82
article

Efficient removal of high concentrations of sulfate, chloride, and total hardness from industrial effluents using nanofiltration membrane technology

Vahid Javanbakht, Mohsen Teimouri
article en
1 citations

Abstract

Sulfate ions, chloride ions, and water hardness represent significant challenges in the treatment of industrial effluents. In this study, a polyamide spiral-wound nanofiltration membrane was applied under various operating conditions to remove these contaminants. Removal performance for sulfate and chloride ions, total hardness reduction, electrical conductivity reduction, and water recovery was assessed, with pH, feed flow rate, and operating pressure selected as key process variables. The experimental results were analyzed using the Response Surface Methodology–Central Composite Design (RSM–CCD) approach, and a face-centered design was employed to determine the relationships between input variables and output responses. Process optimization identified the optimal operating conditions as 7 bar pressure, 10 L/min feed flow rate, and pH 4.62. Under these conditions, water recovery, sulfate ion removal, total hardness removal, chloride ion removal, and electrical conductivity reduction reached 29.9%, 99.4%, 97.7%, 80.9%, and 92.23%, respectively. Recovery rate increased with higher operating pressure and decreased with increased feed flow rate, with minimal dependence on pH. Sulfate removal was strongly dependent on pressure, showing a slight decrease at higher pH values, while total hardness removal followed a similar trend with weaker pH sensitivity. Chloride removal exhibited lower pressure dependence but increased with pH. Given the high contaminant removal efficiencies achieved without the use of chemical additives and with moderate energy consumption, the polyamide spiral-wound nanofiltration process is demonstrated to be an effective and sustainable method for treating industrial effluents.

Discover Applied SciencesVol. 7(9)
Academic Center for Education, Culture and Research (IR), University of Isfahan (IR)
Clean water and sanitation
Openalex Percentile: Top 23%
Membrane Separation Technologies
0.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.