Research on the Localization Method of Ground Electrode Current Field Signal Based on Fractional Fourier Transform

Aiming at the problem of a lack of positioning satellites and no available beacons in underground space, an injected ground electrode current field signal localization method is proposed. An extremely low-frequency current field signal is applied to two pairs of electrodes inserted into the earth to form a ground current field underground, and the ground electrode current field signal detected at the detection end is used for localization, which can effectively provide reference localization for the underground space when the satellite positioning fails. On this basis, considering that the ground electrode current field signal is susceptible to the influence of the geological structure, electromagnetic interference, and the complexity of the propagation path during underground transmission, which results in the signal showing strong non-stationary characteristics, it is difficult for the traditional time–frequency analysis method to accurately extract stable and reliable positioning characteristics. In order to improve the signal-processing accuracy and robustness, this paper introduces fractional Fourier transform (FRFT) to process the detected signals, and focuses the signal energy more effectively under the optimal order. In order to verify the effectiveness of the localization method, several experiments on the localization of ground electrode current field signals are carried out in the underground space. The experimental results show that, in the positioning environment of more than 10,000 square meters, the average positioning error is 6.896 m. The application of this method will provide a solid technical support for life rescue in underground space, provide the ‘last protection’ for rescue, and complete the life chain of emergency first aid, which has an important application prospect and practical value.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-08-25
DOI
https://doi.org/10.3390/electronics14173380
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the Localization Method of Ground Electrode Current Field Signal Based on Fractional Fourier Transform

Zhong Su, Xiangxian Yao, Yanke Wang, Sirui Chu et al.
1 links
Electronics
Advanced Electrical Measurement Techniques
article

Research on the Localization Method of Ground Electrode Current Field Signal Based on Fractional Fourier Transform

Zhong Su, Xiangxian Yao, Yanke Wang, Sirui Chu, Xianyue Gu, Hui Zhao, Zhongao Ling
article en

Abstract

Aiming at the problem of a lack of positioning satellites and no available beacons in underground space, an injected ground electrode current field signal localization method is proposed. An extremely low-frequency current field signal is applied to two pairs of electrodes inserted into the earth to form a ground current field underground, and the ground electrode current field signal detected at the detection end is used for localization, which can effectively provide reference localization for the underground space when the satellite positioning fails. On this basis, considering that the ground electrode current field signal is susceptible to the influence of the geological structure, electromagnetic interference, and the complexity of the propagation path during underground transmission, which results in the signal showing strong non-stationary characteristics, it is difficult for the traditional time–frequency analysis method to accurately extract stable and reliable positioning characteristics. In order to improve the signal-processing accuracy and robustness, this paper introduces fractional Fourier transform (FRFT) to process the detected signals, and focuses the signal energy more effectively under the optimal order. In order to verify the effectiveness of the localization method, several experiments on the localization of ground electrode current field signals are carried out in the underground space. The experimental results show that, in the positioning environment of more than 10,000 square meters, the average positioning error is 6.896 m. The application of this method will provide a solid technical support for life rescue in underground space, provide the ‘last protection’ for rescue, and complete the life chain of emergency first aid, which has an important application prospect and practical value.

ElectronicsVol. 14(17)
Beijing Information Science & Technology University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Beijing Municipality
Openalex Percentile: Top 79%
Advanced Electrical Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.