Absolute Quantitation of Coeluting Impurities in Peptide Drugs Using High Resolution Mass Spectrometry: Glucagon a Case Study in Pharmaceutical Development

Synthetic peptide-based drugs provide customized therapeutic solutions, but developing a peptide medicine presents various challenges, especially in terms of impurity management. This holds true when traditional techniques like RP-HPLC fail to separate low-abundance coeluting impurities. In this regard, liquid chromatography combined with high-resolution mass spectrometry (LC-HRMS) has proven to be effective for identifying and characterizing peptide impurities, although its application for accurate quantitation is still limited. This study developed and validated two quantitation strategies using UPLC-HRMS, employing full scan and pseudo-MRM (<i>p</i>-MRM) modes, to identify and accurately quantify two structurally similar coeluting peptide impurities (des-Gly<sup>4</sup> glucagon and des-Thr<sup>5</sup> glucagon) observed in synthetic glucagon. The methods exhibited high specificity and demonstrated good linearity (<i>R</i><sup>2</sup> > 0.99) across a concentration range of 0.25-25 μg/mL. The limits of detection (LODs) for des-Gly<sup>4</sup>-glucagon and des-Thr<sup>5</sup>-glucagon were determined to be as low as 0.01% and 0.02%, with limits of quantitation (LOQs) at 0.02% and 0.04%, respectively. Precision (RSD%) was recorded at less than 10%, and recovery ranged from 100% to 120%. A comparative analysis of the results indicated that both quantifitation methods performed similarly in terms of accuracy, precision, and recovery, producing comparable impurity estimates in three glucagon API samples. However, <i>p</i>-MRM showed slightly better linearity and sensitivity compared to the full scan EIC-based quantitation method.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2025-08-26
DOI
https://doi.org/10.1021/jasms.5c00105
Citations
2
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.51
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Absolute Quantitation of Coeluting Impurities in Peptide Drugs Using High Resolution Mass Spectrometry: Glucagon a Case Study in Pharmaceutical Development

Kaustubh Acharyya, Vasanthakumar G. Ramu, Anusha Kodidasu
2 citations
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
1.51
article

Absolute Quantitation of Coeluting Impurities in Peptide Drugs Using High Resolution Mass Spectrometry: Glucagon a Case Study in Pharmaceutical Development

Kaustubh Acharyya, Vasanthakumar G. Ramu, Anusha Kodidasu
article en
2 citations

Abstract

Synthetic peptide-based drugs provide customized therapeutic solutions, but developing a peptide medicine presents various challenges, especially in terms of impurity management. This holds true when traditional techniques like RP-HPLC fail to separate low-abundance coeluting impurities. In this regard, liquid chromatography combined with high-resolution mass spectrometry (LC-HRMS) has proven to be effective for identifying and characterizing peptide impurities, although its application for accurate quantitation is still limited. This study developed and validated two quantitation strategies using UPLC-HRMS, employing full scan and pseudo-MRM (<i>p</i>-MRM) modes, to identify and accurately quantify two structurally similar coeluting peptide impurities (des-Gly<sup>4</sup> glucagon and des-Thr<sup>5</sup> glucagon) observed in synthetic glucagon. The methods exhibited high specificity and demonstrated good linearity (<i>R</i><sup>2</sup> > 0.99) across a concentration range of 0.25-25 μg/mL. The limits of detection (LODs) for des-Gly<sup>4</sup>-glucagon and des-Thr<sup>5</sup>-glucagon were determined to be as low as 0.01% and 0.02%, with limits of quantitation (LOQs) at 0.02% and 0.04%, respectively. Precision (RSD%) was recorded at less than 10%, and recovery ranged from 100% to 120%. A comparative analysis of the results indicated that both quantifitation methods performed similarly in terms of accuracy, precision, and recovery, producing comparable impurity estimates in three glucagon API samples. However, <i>p</i>-MRM showed slightly better linearity and sensitivity compared to the full scan EIC-based quantitation method.

Journal of the American Society for Mass SpectrometryVol. 36(10)
Alembic Pharmaceuticals (India) (IN)
Openalex Percentile: Top 16%
Mass Spectrometry Techniques and Applications
1.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Absolute Quantitation of Coeluting Impurities in Peptide Drugs Using High Resolution Mass Spectrometry: Glucagon a Case Study in Pharmaceutical Development — Kaustubh Acharyya, Vasanthakumar G. Ramu, et al. · Journal of the American Society for Mass Spectrometry (2025) | TGRS Research Map | TGRS