Stimuli-Responsive Luminophore Drives Mechanism Switch for Highly Efficient Electrochemiluminescence Immunosensing

Although widely used in clinical diagnostics, the sensitivity of electrochemiluminescence (ECL) bead-based immunoassays is intrinsically limited by the reaction mechanism driving the emission of [Ru(bpy)<sub>3</sub>]<sup>2+</sup> on the bead surface. Depending mostly on the coreactant oxidation, the 'remote' pathway is hindered by the slow coreactant oxidation rate and the short half-lives of electrogenerated radicals. In this work, we synthesized a [Ru(bpy)<sub>3</sub>]<sup>2+</sup> derivative featuring a stimuli-responsive disulfide bond in its linker to the bead. Electrogenerated tri-<i>n</i>-propylamine (TPrA) neutral radicals reduce disulfide moieties, electrochemically inducing the release of Ru(II) labels in solution and thereby leading to an unprecedented mechanism shift toward the more efficient "homogeneous" ECL pathway. Leveraging ICP-MS, ECL microscopy, and finite element simulations, we demonstrate rapid bond cleavage and an impressive signal enhancement of up to 613%. Using an experimental configuration designed to emulate commercial clinical analysis, we developed an ECL-based immunoassay for the rapid detection of the SARS-CoV-2 Spike (S) protein in whole virus samples from swab formulations. The immunosensor incorporating the cleavable luminophore demonstrated a 40% lower detection limit and a 2-fold increase in sensitivity, while reducing TPrA consumption by 72%. These findings establish stimuli-responsive luminophores as a groundbreaking class of ECL labels, promising substantial improvements in the sensitivity of commercial biosensors.

Authors

Institutions

Publication Details

Journal
Journal of the American Chemical Society
Published
2025-08-26
DOI
https://doi.org/10.1021/jacs.5c10211
Citations
7
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
5.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stimuli-Responsive Luminophore Drives Mechanism Switch for Highly Efficient Electrochemiluminescence Immunosensing

Alessia Marconi, Matteo Calvaresi, Giulia Ferrari, Isabella Silvia Rimoldi et al.
7 citations
Journal of the American Chemical Society
Advanced biosensing and bioanalysis techniques
5.64
article

Stimuli-Responsive Luminophore Drives Mechanism Switch for Highly Efficient Electrochemiluminescence Immunosensing

Alessia Marconi, Matteo Calvaresi, Giulia Ferrari, Isabella Silvia Rimoldi, Luisa De Cola, Giorgio Facchetti, Giovanni Valenti, Luca Prodi, Alessandro Fracassa, Maria Vittoria Balli, Lorenzo Arnal
article en
7 citations

Abstract

Although widely used in clinical diagnostics, the sensitivity of electrochemiluminescence (ECL) bead-based immunoassays is intrinsically limited by the reaction mechanism driving the emission of [Ru(bpy)<sub>3</sub>]<sup>2+</sup> on the bead surface. Depending mostly on the coreactant oxidation, the 'remote' pathway is hindered by the slow coreactant oxidation rate and the short half-lives of electrogenerated radicals. In this work, we synthesized a [Ru(bpy)<sub>3</sub>]<sup>2+</sup> derivative featuring a stimuli-responsive disulfide bond in its linker to the bead. Electrogenerated tri-<i>n</i>-propylamine (TPrA) neutral radicals reduce disulfide moieties, electrochemically inducing the release of Ru(II) labels in solution and thereby leading to an unprecedented mechanism shift toward the more efficient "homogeneous" ECL pathway. Leveraging ICP-MS, ECL microscopy, and finite element simulations, we demonstrate rapid bond cleavage and an impressive signal enhancement of up to 613%. Using an experimental configuration designed to emulate commercial clinical analysis, we developed an ECL-based immunoassay for the rapid detection of the SARS-CoV-2 Spike (S) protein in whole virus samples from swab formulations. The immunosensor incorporating the cleavable luminophore demonstrated a 40% lower detection limit and a 2-fold increase in sensitivity, while reducing TPrA consumption by 72%. These findings establish stimuli-responsive luminophores as a groundbreaking class of ECL labels, promising substantial improvements in the sensitivity of commercial biosensors.

Journal of the American Chemical SocietyVol. 147(39)
Karlsruhe Institute of Technology (DE), University of Milan (IT), Azienda USL di Bologna (IT), University of Bologna (IT)
Affordable and clean energy
Openalex Percentile: Top 4%
Advanced biosensing and bioanalysis techniques
5.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.