Non-Direct Contact ECG Signal Classification Using a Hybrid Deep Learning Framework With Validation in Bedside Heart Rate Variability Analysis

In recent years, the demand for smart healthcare solutions have heightened the need for accuracy, reliability, and comfort in bedside ECG recording and analysis. This study presents a bedside non-direct contact ECG recording system based on capacitive coupling electrocardiography (cECG) and verifies its performance in accurately capturing Heart Rate Variability (HRV) during the night. Firstly, cECG collects ECG data through clothing, avoiding skin irritation from conventional wet electrodes. Secondly, leveraging the unique characteristics of cECG signals, a deep learning framework assesses the quality of cECG, filtering noise and identifying off-bed information, enhancing HRV analysis precision. Subsequently, the system was employed to recording sleep data from 6 subjects overnight, with our proposed algorithm utilized for signal quality assessment (SQA) and HRV analysis. Finally, HRV features were compared with synchronously collected wet electrode ECG signals, encompassing time domain features, frequency domain features, and nonlinear features, totaling 13 HRV features. Experimental findings demonstrate that for the SQA task, the model achieved a classification accuracy of 94.7%, with a Recall of 0.941, Precision of 0.940, F1 score of 0.941, and Cohen's Kappa of 0.927. The accuracy of on/off-bed monitoring reached 99.79%. Additionally, HRV features showed a strong correlation with the reference ECG. In the time-domain metrics, the largest mean absolute percentage error (MAPE) is for PNN50, with a value of 8.148%. In the frequency-domain features, the largest MAPE is for HF, with a value of 13.253%. For nonlinear features, the largest MAPE is for SD1, with a value of 5.182%. Generally, the system exhibited a reliable solution for cECG recording, on/off-bed status detection, and bedside HRV analysis.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-08-25
DOI
https://doi.org/10.1109/jbhi.2025.3601807
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Direct Contact ECG Signal Classification Using a Hybrid Deep Learning Framework With Validation in Bedside Heart Rate Variability Analysis

Yunyi Jiang, Zhijun Xiao, Chenxi Yang, Fei Ding et al.
IEEE Journal of Biomedical and Health Informatics
Non-Invasive Vital Sign Monitoring
article

Non-Direct Contact ECG Signal Classification Using a Hybrid Deep Learning Framework With Validation in Bedside Heart Rate Variability Analysis

Yunyi Jiang, Zhijun Xiao, Chenxi Yang, Fei Ding, Maarten De Vos, Minghui Zhao, Christos Chatzichristos, Chengyu Liu, Jianqing Li
article en

Abstract

In recent years, the demand for smart healthcare solutions have heightened the need for accuracy, reliability, and comfort in bedside ECG recording and analysis. This study presents a bedside non-direct contact ECG recording system based on capacitive coupling electrocardiography (cECG) and verifies its performance in accurately capturing Heart Rate Variability (HRV) during the night. Firstly, cECG collects ECG data through clothing, avoiding skin irritation from conventional wet electrodes. Secondly, leveraging the unique characteristics of cECG signals, a deep learning framework assesses the quality of cECG, filtering noise and identifying off-bed information, enhancing HRV analysis precision. Subsequently, the system was employed to recording sleep data from 6 subjects overnight, with our proposed algorithm utilized for signal quality assessment (SQA) and HRV analysis. Finally, HRV features were compared with synchronously collected wet electrode ECG signals, encompassing time domain features, frequency domain features, and nonlinear features, totaling 13 HRV features. Experimental findings demonstrate that for the SQA task, the model achieved a classification accuracy of 94.7%, with a Recall of 0.941, Precision of 0.940, F1 score of 0.941, and Cohen's Kappa of 0.927. The accuracy of on/off-bed monitoring reached 99.79%. Additionally, HRV features showed a strong correlation with the reference ECG. In the time-domain metrics, the largest mean absolute percentage error (MAPE) is for PNN50, with a value of 8.148%. In the frequency-domain features, the largest MAPE is for HF, with a value of 13.253%. For nonlinear features, the largest MAPE is for SD1, with a value of 5.182%. Generally, the system exhibited a reliable solution for cECG recording, on/off-bed status detection, and bedside HRV analysis.

IEEE Journal of Biomedical and Health InformaticsVol. 30(3)
Nanjing University of Posts and Telecommunications (CN), State Key Laboratory of Digital Medical Engineering (CN), Southeast University (CN), KU Leuven (BE)
National Natural Science Foundation of China, Natural Science Foundation of Jiangsu Province, Vlaamse regering
Openalex Percentile: Top 79%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.