Microfluidic Electrochemical Impedance Sensor for Hematological Tests of Blood under Different Osmotic Conditions

Blood tests are widely used to assess a patient's health status. Microfluidics, in combination with electrochemical impedance spectroscopy (MEIS), opens up great prospects for blood analysis. This study aimed to improve the MEIS blood tests. The shape and corpuscular volume of erythrocytes are vital to health care. Erythrocytes change their shape and dielectric properties under different osmolality conditions. Phosphate-buffered saline (PBS) was used to prepare an isotonic solution. Adding salt to PBS induces a hypertonic state. Dilution of PBS with water led to a hypotonic state. Several samples of blood suspensions were prepared with different tonicities. Optical and holotomographic microscopy were used to obtain images of erythrocytes in solutions with different tonicities. The blood impedance was measured by using a two-electrode system. A theoretical approach based on effective medium theory was adopted to analyze the impedance spectrum. The preferred orientation of erythrocytes in the microchannel and hemoglobin hydration were taken into account. The dielectric properties of the plasma, membrane, and cytoplasm of erythrocytes were determined, and the change in the erythrocyte shape was assessed. The proposed method was applied for partial blood count, which includes erythrocyte count (RBC), hemoglobin level (Hb), hematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and mean corpuscular hemoglobin concentration (MCHC). The accuracy of the blood count was confirmed by routine hematological analysis. Additionally, the viscosity of plasma and erythrocyte intracellular fluid was estimated. These results provide a new method of blood testing and could become a valuable tool for point-of-care diagnostics.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-08-26
DOI
https://doi.org/10.1021/acs.analchem.5c01251
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microfluidic Electrochemical Impedance Sensor for Hematological Tests of Blood under Different Osmotic Conditions

Sung Yang, Minkook Son, Ye Sung Lee, A. I. Zhbanov et al.
Analytical Chemistry
Microfluidic and Bio-sensing Technologies
article

Microfluidic Electrochemical Impedance Sensor for Hematological Tests of Blood under Different Osmotic Conditions

Sung Yang, Minkook Son, Ye Sung Lee, A. I. Zhbanov, Byung Jun Kim
article en

Abstract

Blood tests are widely used to assess a patient's health status. Microfluidics, in combination with electrochemical impedance spectroscopy (MEIS), opens up great prospects for blood analysis. This study aimed to improve the MEIS blood tests. The shape and corpuscular volume of erythrocytes are vital to health care. Erythrocytes change their shape and dielectric properties under different osmolality conditions. Phosphate-buffered saline (PBS) was used to prepare an isotonic solution. Adding salt to PBS induces a hypertonic state. Dilution of PBS with water led to a hypotonic state. Several samples of blood suspensions were prepared with different tonicities. Optical and holotomographic microscopy were used to obtain images of erythrocytes in solutions with different tonicities. The blood impedance was measured by using a two-electrode system. A theoretical approach based on effective medium theory was adopted to analyze the impedance spectrum. The preferred orientation of erythrocytes in the microchannel and hemoglobin hydration were taken into account. The dielectric properties of the plasma, membrane, and cytoplasm of erythrocytes were determined, and the change in the erythrocyte shape was assessed. The proposed method was applied for partial blood count, which includes erythrocyte count (RBC), hemoglobin level (Hb), hematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and mean corpuscular hemoglobin concentration (MCHC). The accuracy of the blood count was confirmed by routine hematological analysis. Additionally, the viscosity of plasma and erythrocyte intracellular fluid was estimated. These results provide a new method of blood testing and could become a valuable tool for point-of-care diagnostics.

Analytical ChemistryVol. 97(39)
Gwangju Institute of Science and Technology (KR), Advanced Inhalation Therapies (Israel) (IL), Robotics Research (United States) (US), Siemens Healthcare (United States) (US), Dong-A University (KR)
National Research Foundation of Korea
Affordable and clean energy
Openalex Percentile: Top 79%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.