Vacuum Modular Concept, a new technique to measure air permeability: application to anisotropy in reinforced concrete

The permeability of concrete is a key parameter to evaluate the durability of reinforced concrete structures. In the nuclear field, the tightness of containment buildings largely depends on the low permeability of prestressed concrete. These structures are heavily reinforced raising the question of how reinforcement bars and prestressing cables affect the apparent permeability compared to plain concrete. Usual standardized permeability tests have limitations. The small sample size makes it challenging to study the effects of reinforcement. Additionally, confinement within test cells can alter interface quality, potentially closing cracks in damaged concrete. This can modify the flow characteristics and impact the representativeness of the measured permeability. To address these issues, a new apparatus has been developed to measure permeability under vacuum for reinforced concrete elements. The measurement is performed on prismatic specimens in two directions. This paper presents the system and its validation on plain concrete, as a preliminary step before applications on reinforced concrete. The results indicate a significant anisotropy in permeability depending on the orientation of reinforcement bars. The experiments reveal the minimal resistance of steel-concrete interfaces to pressure gradients, irrespective of the saturation degree. • Creation and validation of a new permeability measurement system • Measurement in vacuum and steady state • Comparison with the conventional Cembureau permeameter • Demonstration of permeability anisotropy associated with the presence and orientation of reinforcement • Preferential flow at the steel-concrete interface • proposal of an effective permeability to take into account the presence of reinforcements

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2025-08-25
DOI
https://doi.org/10.1016/j.jobe.2025.113897
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vacuum Modular Concept, a new technique to measure air permeability: application to anisotropy in reinforced concrete

Hugo Cagnon, David Bouhjiti, Jacques Jabbour, Joe Maalouf et al.
1 links
Journal of Building Engineering
Concrete Corrosion and Durability
article

Vacuum Modular Concept, a new technique to measure air permeability: application to anisotropy in reinforced concrete

Hugo Cagnon, David Bouhjiti, Jacques Jabbour, Joe Maalouf, Stéphane Multon, Jérôme Verdier
article en

Abstract

The permeability of concrete is a key parameter to evaluate the durability of reinforced concrete structures. In the nuclear field, the tightness of containment buildings largely depends on the low permeability of prestressed concrete. These structures are heavily reinforced raising the question of how reinforcement bars and prestressing cables affect the apparent permeability compared to plain concrete. Usual standardized permeability tests have limitations. The small sample size makes it challenging to study the effects of reinforcement. Additionally, confinement within test cells can alter interface quality, potentially closing cracks in damaged concrete. This can modify the flow characteristics and impact the representativeness of the measured permeability. To address these issues, a new apparatus has been developed to measure permeability under vacuum for reinforced concrete elements. The measurement is performed on prismatic specimens in two directions. This paper presents the system and its validation on plain concrete, as a preliminary step before applications on reinforced concrete. The results indicate a significant anisotropy in permeability depending on the orientation of reinforcement bars. The experiments reveal the minimal resistance of steel-concrete interfaces to pressure gradients, irrespective of the saturation degree. • Creation and validation of a new permeability measurement system • Measurement in vacuum and steady state • Comparison with the conventional Cembureau permeameter • Demonstration of permeability anisotropy associated with the presence and orientation of reinforcement • Preferential flow at the steel-concrete interface • proposal of an effective permeability to take into account the presence of reinforcements

Journal of Building EngineeringVol. 112
Institut de Radioprotection et de Sûreté Nucléaire (FR), Université Toulouse III - Paul Sabatier (FR), Université Fédérale de Toulouse Midi-Pyrénées (FR), Laboratoire Matériaux et Durabilité des Constructions (FR), Autorité de sûreté nucléaire et de radioprotection (FR), Université de Picardie Jules Verne (FR)
American Society of Neuroradiology
Sustainable cities and communities
Openalex Percentile: Top 77%
Concrete Corrosion and Durability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.