A retrospective outcomes study 25-gauge 10,000 CPM beveled-tip and 25-gauge flat-tip microincision vitrectomy for proliferative diabetic retinopathy treatment
In the surgical treatment of PDR, the 25G 10K cpm beveled-tip MIVS group showed no statistically significant difference compared to conventional 25G flat-tip MIVS in terms of visual acuity improvement and postoperative intraocular pressure. However, the former demonstrated advantages such as reduced surgical time, decreased intraoperative use of electrocoagulation, and fewer instrument exchanges within the eye, providing robust evidence for its efficacy in PDR surgical management.