Successful Colonic Stenting Across the Ileocecal Valve With Severe Malignant Stenosis Using Ultra‐thin Scope and Single‐balloon Overtube

Self-expanding metallic stents (SEMSs) are an established palliative option for malignant colonic obstruction, including in cases with proximal lesions. However, SEMS placement across the ileocecal valve (ICV) can be technically challenging because of the anatomical curvature and luminal stenosis. Herein, we report a successful case of colonic stenting for a malignant ileocecal obstruction using an ultra-thin scope and a single-balloon overtube. A 72-year-old man with alcoholic cirrhosis and multiple liver metastases presented with malignant ileocecal obstruction. Given his inoperability, palliative SEMS placement was attempted. Colonoscopy showed a circumferential tumor in the ileocecum, with no passage of contrast medium into the ileum. Guidewire insertion across the ICV failed because of the inability to visualize the direction of the ileal lumen. To overcome this, we used a rescue technique with an ultra-thin scope and a single-balloon overtube. After placing the overtube in the ascending colon, the ultra-thin scope was advanced through it to explore the stenotic lumen directly. This allowed safe insertion of the guidewire into the proximal lumen of the stenosis. The ultra-thin scope was withdrawn, and a standard scope was inserted over the guidewire. Finally, a SEMS was deployed across the ICV through the scope. The patient's obstructive symptoms were resolved without complications, and he was discharged 7 days later. This case demonstrates that in cases of malignant ileocecal obstruction where SEMS placement using conventional methods is difficult, a rescue technique using an ultra-thin scope with a single-balloon overtube may be a viable alternative.

Authors

Institutions

Publication Details

Journal
DEN Open
Published
2025-08-25
DOI
https://doi.org/10.1002/deo2.70190
Primary Topic
Esophageal and GI Pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Successful Colonic Stenting Across the Ileocecal Valve With Severe Malignant Stenosis Using Ultra‐thin Scope and Single‐balloon Overtube

Masayoshi Ko, Hiroshi Numao, Masaki Munakata, Takato Maeda et al.
DEN Open
Esophageal and GI Pathology
article

Successful Colonic Stenting Across the Ileocecal Valve With Severe Malignant Stenosis Using Ultra‐thin Scope and Single‐balloon Overtube

Masayoshi Ko, Hiroshi Numao, Masaki Munakata, Takato Maeda, Norihiro Hanabata, Koji Shimaya, Shohei Igarashi, Hirotake Sakuraba
article en

Abstract

Self-expanding metallic stents (SEMSs) are an established palliative option for malignant colonic obstruction, including in cases with proximal lesions. However, SEMS placement across the ileocecal valve (ICV) can be technically challenging because of the anatomical curvature and luminal stenosis. Herein, we report a successful case of colonic stenting for a malignant ileocecal obstruction using an ultra-thin scope and a single-balloon overtube. A 72-year-old man with alcoholic cirrhosis and multiple liver metastases presented with malignant ileocecal obstruction. Given his inoperability, palliative SEMS placement was attempted. Colonoscopy showed a circumferential tumor in the ileocecum, with no passage of contrast medium into the ileum. Guidewire insertion across the ICV failed because of the inability to visualize the direction of the ileal lumen. To overcome this, we used a rescue technique with an ultra-thin scope and a single-balloon overtube. After placing the overtube in the ascending colon, the ultra-thin scope was advanced through it to explore the stenotic lumen directly. This allowed safe insertion of the guidewire into the proximal lumen of the stenosis. The ultra-thin scope was withdrawn, and a standard scope was inserted over the guidewire. Finally, a SEMS was deployed across the ICV through the scope. The patient's obstructive symptoms were resolved without complications, and he was discharged 7 days later. This case demonstrates that in cases of malignant ileocecal obstruction where SEMS placement using conventional methods is difficult, a rescue technique using an ultra-thin scope with a single-balloon overtube may be a viable alternative.

DEN OpenVol. 6(1)
Hirosaki University (JP), Aomori Prefectural Central Hospital (JP)
Openalex Percentile: Top 64%
Esophageal and GI Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.