Cable Joints for 6- to 500-kV Cable Lines with Polymer Insulation (Review)

This article considers current issues of optimization of design and manufacturing technology of cable joints for 6- to 500-kV polymer-insulated cable lines. Special design and process design solutions aimed at increasing the reliability of cable joints are considered, including the introduction of an additional insulation layer and the use of stress cones and electrically strong gels and liquids, as well as internal screens and semiconducting plates. For voltages up to 35 kV, it is recommended to use heat-shrink sleeves, semiconducting plates, and specialized insulating compounds; for lines of 35 kV and above, stress cones, built-in screens, and special coatings are mainly used. The importance of choosing optimal insulating materials and improving the methods for calculating electrical strength to ensure the reliability of high- and extra-high-voltage cable joints is noted.

Authors

Institutions

Publication Details

Journal
Russian Electrical Engineering
Published
2025-04-01
DOI
https://doi.org/10.3103/s1068371225700361
Primary Topic
Material Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cable Joints for 6- to 500-kV Cable Lines with Polymer Insulation (Review)

A. A. Nesterenko, S. A. Elfimov, V. N. Varivodov, D. V. Golubev et al.
Russian Electrical Engineering
Material Properties and Applications
article

Cable Joints for 6- to 500-kV Cable Lines with Polymer Insulation (Review)

A. A. Nesterenko, S. A. Elfimov, V. N. Varivodov, D. V. Golubev, D. I. Kovalev
article en

Abstract

This article considers current issues of optimization of design and manufacturing technology of cable joints for 6- to 500-kV polymer-insulated cable lines. Special design and process design solutions aimed at increasing the reliability of cable joints are considered, including the introduction of an additional insulation layer and the use of stress cones and electrically strong gels and liquids, as well as internal screens and semiconducting plates. For voltages up to 35 kV, it is recommended to use heat-shrink sleeves, semiconducting plates, and specialized insulating compounds; for lines of 35 kV and above, stress cones, built-in screens, and special coatings are mainly used. The importance of choosing optimal insulating materials and improving the methods for calculating electrical strength to ensure the reliability of high- and extra-high-voltage cable joints is noted.

Russian Electrical EngineeringVol. 96(4)
Moscow Power Engineering Institute (RU)
Affordable and clean energy
Openalex Percentile: Top 65%
Material Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.