Analysis and Design of Multistoried Building By Using Software For Different Earthquake Zones

This study presents a comprehensive analysis and design of a multistoried G+16 L-shaped building using structural analysis software under different seismic zones (II to V), focusing on the impact of shear wall inclusion on structural performance. Five models were developed: one without shear walls and four with shear walls placed in zones of increasing seismic intensity. The investigation evaluates storey drift and storey shear parameters to assess lateral load resistance. Results reveal that the model without shear walls (Model-1) exhibits the highest storey drift and lowest shear resistance, indicating poor seismic performance. In contrast, models with shear walls (Models 2–5) show substantial improvements in both drift control and shear resistance, with Model-3 (Zone III) demonstrating the most balanced performance. The study confirms that the inclusion of shear walls significantly enhances the structural stability and seismic resilience of multistoried buildings, with increased efficiency in higher seismic zones.

Authors

Publication Details

Journal
International Journal for Research in Applied Science and Engineering Technology
Published
2025-08-25
DOI
https://doi.org/10.22214/ijraset.2025.73767
Primary Topic
Seismic and Structural Analysis of Tall Buildings
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Design of Multistoried Building By Using Software For Different Earthquake Zones

Gunjan Pradiprao Dihiye
International Journal for Research in Applied Science and Engineering Technology
Seismic and Structural Analysis of Tall Buildings
article

Analysis and Design of Multistoried Building By Using Software For Different Earthquake Zones

Gunjan Pradiprao Dihiye
article en

Abstract

This study presents a comprehensive analysis and design of a multistoried G+16 L-shaped building using structural analysis software under different seismic zones (II to V), focusing on the impact of shear wall inclusion on structural performance. Five models were developed: one without shear walls and four with shear walls placed in zones of increasing seismic intensity. The investigation evaluates storey drift and storey shear parameters to assess lateral load resistance. Results reveal that the model without shear walls (Model-1) exhibits the highest storey drift and lowest shear resistance, indicating poor seismic performance. In contrast, models with shear walls (Models 2–5) show substantial improvements in both drift control and shear resistance, with Model-3 (Zone III) demonstrating the most balanced performance. The study confirms that the inclusion of shear walls significantly enhances the structural stability and seismic resilience of multistoried buildings, with increased efficiency in higher seismic zones.

International Journal for Research in Applied Science and Engineering TechnologyVol. 13(8)
Openalex Percentile: Top 77%
Seismic and Structural Analysis of Tall Buildings
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis and Design of Multistoried Building By Using Software For Different Earthquake Zones — Gunjan Pradiprao Dihiye · International Journal for Research in Applied Science and Engineering Technology (2025) | TGRS Research Map | TGRS