Pressure Coupling Chamber for Comparison Calibration of Hydrophones at Frequencies from a Few Hz Up to 1–2 kHz

Abstract This paper presents a novel pressure coupling chamber for calibrating hydrophones in the frequency range from a few Hz to 1–2 kHz. The design uses an array of loudspeakers and a microphone as projectors and a reference sensor, respectively, acoustically coupled through a medium inside the chamber. The projectors are mounted on the chamber walls around the hydrophone's sensitive element to create a homogeneous acoustic field. The chamber's acoustic length is nearly half that of existing designs, significantly extending the high-frequency calibration range. The paper outlines the calibration setup and procedure, validating the new design through comparisons of B&K 8104 and B&K 8106 hydrophone calibrations. The results are consistent with data from the international project “Underwater Acoustic Calibration Standards for Frequencies Below 1 kHz” (15RPT02 UNAC-LOW), supported by EURAMET.

Authors

Institutions

Publication Details

Journal
MAPAN
Published
2025-08-25
DOI
https://doi.org/10.1007/s12647-025-00846-6
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pressure Coupling Chamber for Comparison Calibration of Hydrophones at Frequencies from a Few Hz Up to 1–2 kHz

Ata Can Çorakçı, Alper Biber, Oleksandr Golyk
MAPAN
Flow Measurement and Analysis
article

Pressure Coupling Chamber for Comparison Calibration of Hydrophones at Frequencies from a Few Hz Up to 1–2 kHz

Ata Can Çorakçı, Alper Biber, Oleksandr Golyk
article en

Abstract

Abstract This paper presents a novel pressure coupling chamber for calibrating hydrophones in the frequency range from a few Hz to 1–2 kHz. The design uses an array of loudspeakers and a microphone as projectors and a reference sensor, respectively, acoustically coupled through a medium inside the chamber. The projectors are mounted on the chamber walls around the hydrophone's sensitive element to create a homogeneous acoustic field. The chamber's acoustic length is nearly half that of existing designs, significantly extending the high-frequency calibration range. The paper outlines the calibration setup and procedure, validating the new design through comparisons of B&K 8104 and B&K 8106 hydrophone calibrations. The results are consistent with data from the international project “Underwater Acoustic Calibration Standards for Frequencies Below 1 kHz” (15RPT02 UNAC-LOW), supported by EURAMET.

MAPAN
Gebze Technical University (TR), Türkiye Bilimsel ve Teknolojik Araştırma Kurumu (TR), TÜBİTAK Marmara Research Center (TR)
European Association of National Metrology Institutes, European Metrology Programme for Innovation and Research
Openalex Percentile: Top 75%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.