MRI and 18F-BPA PET-guided targeting in boron neutron capture therapy
In modern Boron neutron capture therapy (BNCT) treatment planning, <sup>18</sup>F-BPA (<sup>18</sup>F-boronophenylalanine) PET (positron emission tomography) imaging is used to assess boron uptake and guide accurate dose delivery. This study evaluates the geometric and dosimetric differences between target volumes defined by MRI (magnetic resonance imaging) and PET images in accelerator-based BNCT using the NeuPex system. The GTV (gross tumor volume) was defined based on MRI (GTV<sub>MRI</sub>) and PET images with SUV thresholds of 2.0 (GTV<sub>PET2.0</sub>) and 2.5 (GTV<sub>PET2.5</sub>) in patients with head-and-neck cancer (HNC) and malignant glioma (MG). GTV<sub>PET2.5</sub> was approximately 50% smaller, while GTV<sub>PET2.0</sub> showed closer volumetric agreement, with ∆V% of 23.52 ± 17.44 (HNC) and 28.71 ± 12.57 (MG), and corresponding Dice similarity coefficients of 0.71 ± 0.14 and 0.86 ± 0.17. Dosimetric analysis revealed that GTV<sub>PET2.0</sub> achieved higher dose coverage than GTV<sub>MRI</sub>, with mean doses of 24.07 ± 6.42 Gy-Eq (HNC) and 26.36 ± 9.77 Gy-Eq (MG), and D<sub>80</sub> values of 19.01 ± 6.90 Gy-Eq and 21.00 ± 7.51 Gy-Eq, respectively. Tumor-to-blood ratio (TBR) and tumor-to-normal ratio (TNR) analyses further indicated substantial heterogeneity in boron uptake, with mean TBR and TNR of 2.71 ± 0.53 and 2.97 ± 0.79 for GTV<sub>PET2.0.</sub> These results suggest that GTV<sub>PET2.0</sub> provides a balanced and biologically relevant target for BNCT planning. A TBR threshold of ≥ 2.0 is proposed as a practical criterion for patient selection. While this study focuses on geometric and dosimetric endpoints, future work correlating these findings with clinical outcomes is warranted. Overall, this study supports the integration of functional PET imaging with anatomical MRI to improve the precision and efficacy of BNCT treatment planning.
Authors
- Ye Cao (ORCID: https://orcid.org/0000-0001-7663-1480)
- Yi-Chiao Teng (ORCID: https://orcid.org/0000-0001-9256-0889)
- Xiaobin Xia
- Jianji Pan (ORCID: https://orcid.org/0000-0002-3211-7874)
- Yisheng Lai (ORCID: https://orcid.org/0000-0002-8026-7949)
- Cairong Hu
- Yuan-Hao Liu
Institutions
- Fujian Medical University (CN)
- Chinese Academy of Sciences (CN)
- Neuboron (China) (CN)
- Shanghai Institute of Applied Physics (CN)
- Fujian Provincial Cancer Hospital (CN)
- Xiamen Chang Gung Hospital (CN)
- University of Chinese Academy of Sciences (CN)
- Nanjing University of Aeronautics and Astronautics (CN)
Publication Details
- Journal
- Scientific Reports
- Published
- 2025-08-25
- DOI
- https://doi.org/10.1038/s41598-025-14642-4
- Citations
- 5
- Primary Topic
- Boron Compounds in Chemistry
- Type
- article
- Field-Weighted Citation Impact
- 6.80
Funders
- National Natural Science Foundation of China
- Ministerio de Economía y Competitividad
- National Key Research and Development Program of China