MRI and 18F-BPA PET-guided targeting in boron neutron capture therapy

In modern Boron neutron capture therapy (BNCT) treatment planning, <sup>18</sup>F-BPA (<sup>18</sup>F-boronophenylalanine) PET (positron emission tomography) imaging is used to assess boron uptake and guide accurate dose delivery. This study evaluates the geometric and dosimetric differences between target volumes defined by MRI (magnetic resonance imaging) and PET images in accelerator-based BNCT using the NeuPex system. The GTV (gross tumor volume) was defined based on MRI (GTV<sub>MRI</sub>) and PET images with SUV thresholds of 2.0 (GTV<sub>PET2.0</sub>) and 2.5 (GTV<sub>PET2.5</sub>) in patients with head-and-neck cancer (HNC) and malignant glioma (MG). GTV<sub>PET2.5</sub> was approximately 50% smaller, while GTV<sub>PET2.0</sub> showed closer volumetric agreement, with ∆V% of 23.52 ± 17.44 (HNC) and 28.71 ± 12.57 (MG), and corresponding Dice similarity coefficients of 0.71 ± 0.14 and 0.86 ± 0.17. Dosimetric analysis revealed that GTV<sub>PET2.0</sub> achieved higher dose coverage than GTV<sub>MRI</sub>, with mean doses of 24.07 ± 6.42 Gy-Eq (HNC) and 26.36 ± 9.77 Gy-Eq (MG), and D<sub>80</sub> values of 19.01 ± 6.90 Gy-Eq and 21.00 ± 7.51 Gy-Eq, respectively. Tumor-to-blood ratio (TBR) and tumor-to-normal ratio (TNR) analyses further indicated substantial heterogeneity in boron uptake, with mean TBR and TNR of 2.71 ± 0.53 and 2.97 ± 0.79 for GTV<sub>PET2.0.</sub> These results suggest that GTV<sub>PET2.0</sub> provides a balanced and biologically relevant target for BNCT planning. A TBR threshold of ≥ 2.0 is proposed as a practical criterion for patient selection. While this study focuses on geometric and dosimetric endpoints, future work correlating these findings with clinical outcomes is warranted. Overall, this study supports the integration of functional PET imaging with anatomical MRI to improve the precision and efficacy of BNCT treatment planning.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-08-25
DOI
https://doi.org/10.1038/s41598-025-14642-4
Citations
5
Primary Topic
Boron Compounds in Chemistry
Type
article
Field-Weighted Citation Impact
6.80

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MRI and 18F-BPA PET-guided targeting in boron neutron capture therapy

Ye Cao, Yi-Chiao Teng, Xiaobin Xia, Jianji Pan et al.
5 citations
Scientific Reports
Boron Compounds in Chemistry
6.80
article

MRI and 18F-BPA PET-guided targeting in boron neutron capture therapy

Ye Cao, Yi-Chiao Teng, Xiaobin Xia, Jianji Pan, Yisheng Lai, Cairong Hu, Yuan-Hao Liu
article en
5 citations

Abstract

In modern Boron neutron capture therapy (BNCT) treatment planning, <sup>18</sup>F-BPA (<sup>18</sup>F-boronophenylalanine) PET (positron emission tomography) imaging is used to assess boron uptake and guide accurate dose delivery. This study evaluates the geometric and dosimetric differences between target volumes defined by MRI (magnetic resonance imaging) and PET images in accelerator-based BNCT using the NeuPex system. The GTV (gross tumor volume) was defined based on MRI (GTV<sub>MRI</sub>) and PET images with SUV thresholds of 2.0 (GTV<sub>PET2.0</sub>) and 2.5 (GTV<sub>PET2.5</sub>) in patients with head-and-neck cancer (HNC) and malignant glioma (MG). GTV<sub>PET2.5</sub> was approximately 50% smaller, while GTV<sub>PET2.0</sub> showed closer volumetric agreement, with ∆V% of 23.52 ± 17.44 (HNC) and 28.71 ± 12.57 (MG), and corresponding Dice similarity coefficients of 0.71 ± 0.14 and 0.86 ± 0.17. Dosimetric analysis revealed that GTV<sub>PET2.0</sub> achieved higher dose coverage than GTV<sub>MRI</sub>, with mean doses of 24.07 ± 6.42 Gy-Eq (HNC) and 26.36 ± 9.77 Gy-Eq (MG), and D<sub>80</sub> values of 19.01 ± 6.90 Gy-Eq and 21.00 ± 7.51 Gy-Eq, respectively. Tumor-to-blood ratio (TBR) and tumor-to-normal ratio (TNR) analyses further indicated substantial heterogeneity in boron uptake, with mean TBR and TNR of 2.71 ± 0.53 and 2.97 ± 0.79 for GTV<sub>PET2.0.</sub> These results suggest that GTV<sub>PET2.0</sub> provides a balanced and biologically relevant target for BNCT planning. A TBR threshold of ≥ 2.0 is proposed as a practical criterion for patient selection. While this study focuses on geometric and dosimetric endpoints, future work correlating these findings with clinical outcomes is warranted. Overall, this study supports the integration of functional PET imaging with anatomical MRI to improve the precision and efficacy of BNCT treatment planning.

Scientific ReportsVol. 15(1)
Fujian Medical University (CN), Chinese Academy of Sciences (CN), Neuboron (China) (CN), Shanghai Institute of Applied Physics (CN), Fujian Provincial Cancer Hospital (CN), Xiamen Chang Gung Hospital (CN), University of Chinese Academy of Sciences (CN), Nanjing University of Aeronautics and Astronautics (CN)
National Natural Science Foundation of China, Ministerio de Economía y Competitividad, National Key Research and Development Program of China
Openalex Percentile: Top 3%
Boron Compounds in Chemistry
6.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.