Mechanism and Material Development of Temperature Activated Bonding Plugging for Lost Circulation Control in Deep Fractured Formations

Summary Lost circulation is a significant challenge during drilling operations. To mitigate this issue in fractured formations, the most commonly used methods are bridging and plugging, which help seal off fractures and prevent the loss of drilling fluids. However, the sealing layer formed by bridging materials is inherently discontinuous, relying on physical forces such as elastic force, friction, and interlocking to maintain its stability. This limits the further enhancement of pressure-bearing performance. Consequently, in deep and ultradeep formations with harsh environments, challenges persist regarding insufficient pressure-bearing capacity for fracture sealing and poor unplugging efficiency. Therefore, enhancing interparticle forces through the introduction of chemical adhesion has become a key strategy to improve the pressure-bearing capacity and overall stability of the sealing layer. To address this technical challenge, we developed a novel core-shell structured plugging agent TPA-1 with high-temperature-activated bonding characteristics. The thermal activation time of TPA-1 at 110~140°C ranges from 2.75 hours to 6.25 hours, ensuring safety during on-site plugging operations. When combined with bridging plugging materials, TPA-1 effectively sealed a 3-mm fracture, achieving a maximum pressure-bearing capacity of 15.4 MPa. Furthermore, when mixed with self-degradable materials for temporary plugging of reservoir fractures, the post-unplugging fracture permeability reached 9785.8 md. The temperature-sensitive adhesive plugging agent TPA-1, as proposed in this study, remains functionally identical to conventional bridging plugging materials at ambient temperature, aiming to provide a simple and highly safe functional adhesive plugging material for field applications.

Authors

Institutions

Publication Details

Journal
SPE Journal
Published
2025-08-25
DOI
https://doi.org/10.2118/228422-pa
Citations
1
Primary Topic
Drilling and Well Engineering
Type
article
Field-Weighted Citation Impact
1.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanism and Material Development of Temperature Activated Bonding Plugging for Lost Circulation Control in Deep Fractured Formations

Yili Kang, Chengyuan Xu, Jingquan Zhong, Shuizhong Luo et al.
1 citations
SPE Journal
Drilling and Well Engineering
1.15
article

Mechanism and Material Development of Temperature Activated Bonding Plugging for Lost Circulation Control in Deep Fractured Formations

Yili Kang, Chengyuan Xu, Jingquan Zhong, Shuizhong Luo, Zhenjiang You, Yingrui Bai, Lei Liu, Mingming Zhu, Xinyue Tang
article en
1 citations

Abstract

Summary Lost circulation is a significant challenge during drilling operations. To mitigate this issue in fractured formations, the most commonly used methods are bridging and plugging, which help seal off fractures and prevent the loss of drilling fluids. However, the sealing layer formed by bridging materials is inherently discontinuous, relying on physical forces such as elastic force, friction, and interlocking to maintain its stability. This limits the further enhancement of pressure-bearing performance. Consequently, in deep and ultradeep formations with harsh environments, challenges persist regarding insufficient pressure-bearing capacity for fracture sealing and poor unplugging efficiency. Therefore, enhancing interparticle forces through the introduction of chemical adhesion has become a key strategy to improve the pressure-bearing capacity and overall stability of the sealing layer. To address this technical challenge, we developed a novel core-shell structured plugging agent TPA-1 with high-temperature-activated bonding characteristics. The thermal activation time of TPA-1 at 110~140°C ranges from 2.75 hours to 6.25 hours, ensuring safety during on-site plugging operations. When combined with bridging plugging materials, TPA-1 effectively sealed a 3-mm fracture, achieving a maximum pressure-bearing capacity of 15.4 MPa. Furthermore, when mixed with self-degradable materials for temporary plugging of reservoir fractures, the post-unplugging fracture permeability reached 9785.8 md. The temperature-sensitive adhesive plugging agent TPA-1, as proposed in this study, remains functionally identical to conventional bridging plugging materials at ambient temperature, aiming to provide a simple and highly safe functional adhesive plugging material for field applications.

SPE JournalVol. 30(10)
Southwest Petroleum University (CN), China University of Petroleum, Beijing (CN), State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation (CN), China University of Petroleum, East China (CN), China National Petroleum Corporation (China) (CN)
Openalex Percentile: Top 19%
Drilling and Well Engineering
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.