Comparative Analysis of Electric Field Simulation Under Isotropic and Anisotropic Bulk Conductivity in DC Bushing

The UHVDC converter transformer valve-side bushing is a critical component in DC transmission systems. However, the anisotropic properties of bushing insulating materials have been overlooked in previous studies. This paper investigated on the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\pm \mathbf{8 0 0 ~ k V}$</tex> converter transformer valve-side bushing by measuring the bulk conductivity of epoxyimpregnated paper flake specimens cut from an actual bushing both parallel and perpendicular to the insulation paper surface. The study revealed that the bulk conductivity in the perpendicular direction was significantly higher than that in the parallel direction. A steady-state coupled electrical-thermalfluid simulation model for the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\pm 800 \text{kV}$</tex> converter transformer valve-side bushing was further established. Simulations were conducted under both isotropic and anisotropic bulk conductivity conditions, and the results were comparatively analyzed. The study revealed that on the bushing epoxy core airgap surface near the shield, isotropic bulk conductivity resulted in minor negative charge accumulation, whereas anisotropic bulk conductivity induced significant negative charge accumulation. Compared to isotropic bulk conductivity, anisotropic conditions reduced the air-gap terminal potential by 14 kV and increased the normal/tangential components of the electric field on the SF6 side of the air-gap surface by <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$1.9 \text{kV} / \text{mm}$</tex> and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.51 \text{kV} / \text{mm}$</tex>, respectively, degrading the insulation performance of the air-gap region.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icempe66159.2025.11123098
Primary Topic
Electronic Packaging and Soldering Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Electric Field Simulation Under Isotropic and Anisotropic Bulk Conductivity in DC Bushing

Ning Guo, Yulin Jiang, Wenhao Gao, Xia Wang et al.
Electronic Packaging and Soldering Technologies
article

Comparative Analysis of Electric Field Simulation Under Isotropic and Anisotropic Bulk Conductivity in DC Bushing

Ning Guo, Yulin Jiang, Wenhao Gao, Xia Wang, Bohan Lan, Weidong Ding
article en

Abstract

The UHVDC converter transformer valve-side bushing is a critical component in DC transmission systems. However, the anisotropic properties of bushing insulating materials have been overlooked in previous studies. This paper investigated on the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\pm \mathbf{8 0 0 ~ k V}$</tex> converter transformer valve-side bushing by measuring the bulk conductivity of epoxyimpregnated paper flake specimens cut from an actual bushing both parallel and perpendicular to the insulation paper surface. The study revealed that the bulk conductivity in the perpendicular direction was significantly higher than that in the parallel direction. A steady-state coupled electrical-thermalfluid simulation model for the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\pm 800 \text{kV}$</tex> converter transformer valve-side bushing was further established. Simulations were conducted under both isotropic and anisotropic bulk conductivity conditions, and the results were comparatively analyzed. The study revealed that on the bushing epoxy core airgap surface near the shield, isotropic bulk conductivity resulted in minor negative charge accumulation, whereas anisotropic bulk conductivity induced significant negative charge accumulation. Compared to isotropic bulk conductivity, anisotropic conditions reduced the air-gap terminal potential by 14 kV and increased the normal/tangential components of the electric field on the SF6 side of the air-gap surface by <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$1.9 \text{kV} / \text{mm}$</tex> and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.51 \text{kV} / \text{mm}$</tex>, respectively, degrading the insulation performance of the air-gap region.

State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
Openalex Percentile: Top 79%
Electronic Packaging and Soldering Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.