Electromagnetic Safety Simulation Study of Electromagnetic Safety Operation on $\pm 800 \text{kV} \pm 500 \text{kV}$ Same-Tower Double-Circuit DC Lines

In this paper, the electromagnetic safety risk of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\pm 800 \text{kV} / \pm 500 \text{kV}$</tex> same-tower double-circuit DC transmission line electrified operation is studied. By establishing electromagnetic field theoretical calculation model and human body multi-physical field finite element simulation model, the electromagnetic exposure level of the operating personnel when overhauling the conductor at different voltage levels is analyzed. The study shows that the induced electric field intensity on the surface of the operator's body, the magnetic induction intensity around the operator, and the induced current level in the body increase as the voltage level of the transmission line increases. The simulation results clearly reveal the potential safety risks of direct exposure of operators to a strong electromagnetic environment, highlighting the need for effective shielding measures. This study provides data support for the electromagnetic safety assessment and protection design of UHV DC transmission lines.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icempe66159.2025.11122953
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electromagnetic Safety Simulation Study of Electromagnetic Safety Operation on $\pm 800 \text{kV} \pm 500 \text{kV}$ Same-Tower Double-Circuit DC Lines

Yinlong Wang, Jie Zhang, Yi Zhang, Ning Xu et al.
High-Voltage Power Transmission Systems
article

Electromagnetic Safety Simulation Study of Electromagnetic Safety Operation on $\pm 800 \text{kV} \pm 500 \text{kV}$ Same-Tower Double-Circuit DC Lines

Yinlong Wang, Jie Zhang, Yi Zhang, Ning Xu, Rui Wang
article en

Abstract

In this paper, the electromagnetic safety risk of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\pm 800 \text{kV} / \pm 500 \text{kV}$</tex> same-tower double-circuit DC transmission line electrified operation is studied. By establishing electromagnetic field theoretical calculation model and human body multi-physical field finite element simulation model, the electromagnetic exposure level of the operating personnel when overhauling the conductor at different voltage levels is analyzed. The study shows that the induced electric field intensity on the surface of the operator's body, the magnetic induction intensity around the operator, and the induced current level in the body increase as the voltage level of the transmission line increases. The simulation results clearly reveal the potential safety risks of direct exposure of operators to a strong electromagnetic environment, highlighting the need for effective shielding measures. This study provides data support for the electromagnetic safety assessment and protection design of UHV DC transmission lines.

State Grid Corporation of China (China) (CN), Tongling University (CN)
Affordable and clean energy
Openalex Percentile: Top 79%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electromagnetic Safety Simulation Study of Electromagnetic Safety Operation on $\pm 800 \text{kV} \pm 500 \text{kV}$ Same-Tower Double-Circuit DC Lines — Yinlong Wang, Jie Zhang, et al. · (2025) | TGRS Research Map | TGRS