Analysis of Influencing Factors of Self-Sustaining Discharge Along Surface of DC GIL/GIS Spacer

To enhance the stability and reliability of GIS/GIL equipment in high-voltage direct current (HVDC) transmission systems, this study considers the multi-physics coupling conditions experienced by basin-type insulators during actual operation. Surface self-sustaining discharge experiments were conducted under the influence of temperature during the adsorption of metallic contaminants. The effects of voltage polarity and temperature on the inception voltage and flashover voltage of DC surface self-sustaining discharges were analyzed and validated. The results show that the inception voltage decreases with increasing temperature. The positive polarity always exhibits a higher inception voltage than the negative polarity, which aligns with the polarity effect observed in highly non-uniform electric fields. The inception voltage under negative polarity remains relatively stable and shows an approximately monotonic decreasing trend. For flashover voltage, a rapid decline is observed at the initial stage under positive polarity, followed by a gradual stabilization, whereas under negative polarity, the initial decline is slower but accelerates significantly in the later stages.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icempe66159.2025.11123060
Primary Topic
Elevator Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Influencing Factors of Self-Sustaining Discharge Along Surface of DC GIL/GIS Spacer

Xu Cai, Junbo Deng, Jindou Shi, Zhuohang Jiang et al.
Elevator Systems and Control
article

Analysis of Influencing Factors of Self-Sustaining Discharge Along Surface of DC GIL/GIS Spacer

Xu Cai, Junbo Deng, Jindou Shi, Zhuohang Jiang, Wei Yin, Xulei Zhao
article en

Abstract

To enhance the stability and reliability of GIS/GIL equipment in high-voltage direct current (HVDC) transmission systems, this study considers the multi-physics coupling conditions experienced by basin-type insulators during actual operation. Surface self-sustaining discharge experiments were conducted under the influence of temperature during the adsorption of metallic contaminants. The effects of voltage polarity and temperature on the inception voltage and flashover voltage of DC surface self-sustaining discharges were analyzed and validated. The results show that the inception voltage decreases with increasing temperature. The positive polarity always exhibits a higher inception voltage than the negative polarity, which aligns with the polarity effect observed in highly non-uniform electric fields. The inception voltage under negative polarity remains relatively stable and shows an approximately monotonic decreasing trend. For flashover voltage, a rapid decline is observed at the initial stage under positive polarity, followed by a gradual stabilization, whereas under negative polarity, the initial decline is slower but accelerates significantly in the later stages.

State Grid Corporation of China (China) (CN), State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
Openalex Percentile: Top 73%
Elevator Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Influencing Factors of Self-Sustaining Discharge Along Surface of DC GIL/GIS Spacer — Xu Cai, Junbo Deng, et al. · (2025) | TGRS Research Map | TGRS