Suppression of Partial Discharge in Package Insulation Under Square-Wave Voltage by Plasma-Enhanced Film Deposition

The rapid development of power modules, characterized by high <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathrm{d} v / \text{dt}$</tex> switching, subjects package insulation to severe electrical stress under square-wave voltage, leading to detrimental partial discharges (PD) at triple point (TP) region. This study introduces a precision atmospheric pressure micro-plasma jet (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mu$</tex>-APPJ) technique using HMDSO precursor to deposit Si-containing dielectric film at metal/insulation interface. By optimizing HMDSO volume fraction (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\phi_{\text {HMDso }}$</tex>), the effect of plasma treatment conditions on PD suppression at 5 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{kHz} / 50 \%$</tex> duty-cycle square-wave voltage is evaluated. The results show that Ar/HMDSO plasma-deposited films are effective in suppressing the PD intensity, but introduce an unanticipated PD phenomenon at the high-level stage. With the increase of HMDSO volume fraction, the maximum PD amplitude of the unpotted sample at <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\phi_{\text {HMDSO }}=0.24 \%$</tex> decreased to 12.25 mV (84.6 % reduction) and the PD is completely suppressed in the high-level stage. The number of PDs of the potted sample is reduced by 56.1 %, with an average amplitude reduction of 53.9 %, and the breakdown voltage is increased to 17 kV. This technique provides a novel approach to improve the insulation reliability of power modules.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icempe66159.2025.11122997
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Suppression of Partial Discharge in Package Insulation Under Square-Wave Voltage by Plasma-Enhanced Film Deposition

Zhi Fang, Fengjie Zhang, Hongtu Cheng, Xiuhan Guan et al.
High voltage insulation and dielectric phenomena
article

Suppression of Partial Discharge in Package Insulation Under Square-Wave Voltage by Plasma-Enhanced Film Deposition

Zhi Fang, Fengjie Zhang, Hongtu Cheng, Xiuhan Guan, Yalin Wang, Xi Zhu, Junhao Xu
article en

Abstract

The rapid development of power modules, characterized by high <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathrm{d} v / \text{dt}$</tex> switching, subjects package insulation to severe electrical stress under square-wave voltage, leading to detrimental partial discharges (PD) at triple point (TP) region. This study introduces a precision atmospheric pressure micro-plasma jet (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mu$</tex>-APPJ) technique using HMDSO precursor to deposit Si-containing dielectric film at metal/insulation interface. By optimizing HMDSO volume fraction (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\phi_{\text {HMDso }}$</tex>), the effect of plasma treatment conditions on PD suppression at 5 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{kHz} / 50 \%$</tex> duty-cycle square-wave voltage is evaluated. The results show that Ar/HMDSO plasma-deposited films are effective in suppressing the PD intensity, but introduce an unanticipated PD phenomenon at the high-level stage. With the increase of HMDSO volume fraction, the maximum PD amplitude of the unpotted sample at <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\phi_{\text {HMDSO }}=0.24 \%$</tex> decreased to 12.25 mV (84.6 % reduction) and the PD is completely suppressed in the high-level stage. The number of PDs of the potted sample is reduced by 56.1 %, with an average amplitude reduction of 53.9 %, and the breakdown voltage is increased to 17 kV. This technique provides a novel approach to improve the insulation reliability of power modules.

Harbin University of Science and Technology (CN), Nanjing Tech University (CN), Shanghai Jiao Tong University (CN)
Affordable and clean energy
Openalex Percentile: Top 84%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.