Development of On-Line Monitoring Device for Interturn Short-Circuit of Dry-Type Air-Core Reactor Based on Star-Arm Current Change Rate

The dry-type air-core reactor often causes the coil to burn due to the interturn short-circuit during operation. The existing non-electrical quantity detection methods such as temperature and smoke, and the electrical quantity detection methods such as partial discharge are not real-time, accurate and sensitive enough, and cannot be warned in time. Therefore, this paper designs an on-line monitoring device for interturn short-circuit of dry-type aircore reactor based on star-arm current change rate. Firstly, the variation rule of star-arm current before and after interturn short-circuit of different types of air-core reactors is analyzed, and the criterion of interturn short-circuit is proposed. Then, based on the principle of electromagnetic induction, a star-shaped arm current self-powered power supply unit is designed to achieve a stable output of isolated <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\pm$</tex> 5 V DC voltage. In order to realize the synchronous acquisition and transmission of multi-star-arm current signals, a 4G wireless transmission unit is further constructed based on ZigBee networking technology, which solves the problem of wiring redundancy and signal interference caused by traditional wired data transmission. Finally, the 66 kV drytype air-core reactor is taken as the experimental object, and the interturn insulation test is carried out by using this system to simulate the interturn short-circuit defect. The experimental results show that the on-line monitoring device designed in this paper can accurately realize the diagnosis and early warning of interturn short-circuit of dry-type air-core reactor.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icempe66159.2025.11123046
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of On-Line Monitoring Device for Interturn Short-Circuit of Dry-Type Air-Core Reactor Based on Star-Arm Current Change Rate

Heqian Liu, Peng Zhang, Ji Liu, Zhongyuan Li et al.
Engineering Applied Research
article

Development of On-Line Monitoring Device for Interturn Short-Circuit of Dry-Type Air-Core Reactor Based on Star-Arm Current Change Rate

Heqian Liu, Peng Zhang, Ji Liu, Zhongyuan Li, Jian Zhang, Min Gu
article en

Abstract

The dry-type air-core reactor often causes the coil to burn due to the interturn short-circuit during operation. The existing non-electrical quantity detection methods such as temperature and smoke, and the electrical quantity detection methods such as partial discharge are not real-time, accurate and sensitive enough, and cannot be warned in time. Therefore, this paper designs an on-line monitoring device for interturn short-circuit of dry-type aircore reactor based on star-arm current change rate. Firstly, the variation rule of star-arm current before and after interturn short-circuit of different types of air-core reactors is analyzed, and the criterion of interturn short-circuit is proposed. Then, based on the principle of electromagnetic induction, a star-shaped arm current self-powered power supply unit is designed to achieve a stable output of isolated <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\pm$</tex> 5 V DC voltage. In order to realize the synchronous acquisition and transmission of multi-star-arm current signals, a 4G wireless transmission unit is further constructed based on ZigBee networking technology, which solves the problem of wiring redundancy and signal interference caused by traditional wired data transmission. Finally, the 66 kV drytype air-core reactor is taken as the experimental object, and the interturn insulation test is carried out by using this system to simulate the interturn short-circuit defect. The experimental results show that the on-line monitoring device designed in this paper can accurately realize the diagnosis and early warning of interturn short-circuit of dry-type air-core reactor.

Harbin University of Science and Technology (CN), Electric Power Research Institute (US), Harbin Electric Corporation (China) (CN), Heilongjiang Electric Power Workers University (CN)
Affordable and clean energy
Openalex Percentile: Top 77%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.