Research and Development on Frequency Domain Dielectric Response Test Device for Transformer Oil-Paper Insulation

The frequency domain dielectric response method has garnered significant attention due to its ability to provide abundant information for non-destructive testing of transformers. However, in the response current of oil paper insulated dielectric reaches picoampere level. Due to the influence of on-site electromagnetic interference, the sampling accuracy is difficult to guarantee. Therefore, the errors will be generated in the obtained frequency-domain dielectric spectra. To resolve these problems, this paper designs a cascaded amplifier topology based on parallel optocoupler isolation drive technology, achieving high-voltage sinusoidal output in the 0.001 Hz to 10 kHz range. The anti-interference capability of the testing system is enhanced through the increasing of the excitation source voltage amplitude. To achieve high-precision and phase-shift-free acquisition of dielectric response micro-currents, an adaptive differential current voltage conversion circuit is constructed for accurate acquisition within the 0.01 pA to 1 mA range. The dielectric response testing system developed in this paper is used to conduct frequency domain spectroscopy tests on in-service transformers. The experiment results demonstrated the accuracy and anti-interference capabilities of the proposed system.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icempe66159.2025.11122979
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research and Development on Frequency Domain Dielectric Response Test Device for Transformer Oil-Paper Insulation

Haiyue Zhang, Limin Qu, Shouming Wang, Ji Liu et al.
Power Transformer Diagnostics and Insulation
article

Research and Development on Frequency Domain Dielectric Response Test Device for Transformer Oil-Paper Insulation

Haiyue Zhang, Limin Qu, Shouming Wang, Ji Liu, H. Xu, Dewen Zhang
article en

Abstract

The frequency domain dielectric response method has garnered significant attention due to its ability to provide abundant information for non-destructive testing of transformers. However, in the response current of oil paper insulated dielectric reaches picoampere level. Due to the influence of on-site electromagnetic interference, the sampling accuracy is difficult to guarantee. Therefore, the errors will be generated in the obtained frequency-domain dielectric spectra. To resolve these problems, this paper designs a cascaded amplifier topology based on parallel optocoupler isolation drive technology, achieving high-voltage sinusoidal output in the 0.001 Hz to 10 kHz range. The anti-interference capability of the testing system is enhanced through the increasing of the excitation source voltage amplitude. To achieve high-precision and phase-shift-free acquisition of dielectric response micro-currents, an adaptive differential current voltage conversion circuit is constructed for accurate acquisition within the 0.01 pA to 1 mA range. The dielectric response testing system developed in this paper is used to conduct frequency domain spectroscopy tests on in-service transformers. The experiment results demonstrated the accuracy and anti-interference capabilities of the proposed system.

Harbin University of Science and Technology (CN), Electric Power Research Institute (US), Harbin Electric Corporation (China) (CN), Heilongjiang Electric Power Workers University (CN)
Affordable and clean energy
Openalex Percentile: Top 79%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research and Development on Frequency Domain Dielectric Response Test Device for Transformer Oil-Paper Insulation — Haiyue Zhang, Limin Qu, et al. · (2025) | TGRS Research Map | TGRS