Research on the Partial Discharge Characteristics of Transformers Under Multiple Types of Voltages Based on DFB Fiber Ultrasonic Sensors

To investigate the partial discharge (PD) characteristics of transformers under different test voltages (power frequency, lightning impulse, and operating overvoltage), this study utilizes DFB fiber-optic ultrasonic sensors to examine the acoustic signal characteristics of PD in an 80 kVA oil-immersed transformer under various voltage types. The experiments reveal that power frequency discharges exhibit short durations in the time domain, with high-frequency components concentrated between <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$50-200 \text{kHz}$</tex> in the frequency domain. Operating overvoltage discharges manifest as dense and chaotic pulse clusters in the time domain, lasting the longest, with low-frequency components concentrated between <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{2 0 - 1 0 0}$</tex> kHz in the frequency domain, and the time-frequency diagram shows uniformly distributed frequency components with slow attenuation. Lightning impulse discharges appear as distinct pulse clusters in the time domain, with the highest amplitudes, and their frequency domain spans <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0-300 \text{kHz}$</tex>, where the lowfrequency band exhibits the highest energy, while highfrequency components remain relatively flat. These findings provide an important basis for a deeper understanding of transformer PD characteristics and ensuring the safe and stable operation of power systems.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icempe66159.2025.11123016
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the Partial Discharge Characteristics of Transformers Under Multiple Types of Voltages Based on DFB Fiber Ultrasonic Sensors

Lifeng Cheng, Zhengyang Liu, Hao Zhan, Jing Zhang et al.
Advanced Sensor and Control Systems
article

Research on the Partial Discharge Characteristics of Transformers Under Multiple Types of Voltages Based on DFB Fiber Ultrasonic Sensors

Lifeng Cheng, Zhengyang Liu, Hao Zhan, Jing Zhang, Zhenbo Du, Yulong Ma
article en

Abstract

To investigate the partial discharge (PD) characteristics of transformers under different test voltages (power frequency, lightning impulse, and operating overvoltage), this study utilizes DFB fiber-optic ultrasonic sensors to examine the acoustic signal characteristics of PD in an 80 kVA oil-immersed transformer under various voltage types. The experiments reveal that power frequency discharges exhibit short durations in the time domain, with high-frequency components concentrated between <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$50-200 \text{kHz}$</tex> in the frequency domain. Operating overvoltage discharges manifest as dense and chaotic pulse clusters in the time domain, lasting the longest, with low-frequency components concentrated between <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{2 0 - 1 0 0}$</tex> kHz in the frequency domain, and the time-frequency diagram shows uniformly distributed frequency components with slow attenuation. Lightning impulse discharges appear as distinct pulse clusters in the time domain, with the highest amplitudes, and their frequency domain spans <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0-300 \text{kHz}$</tex>, where the lowfrequency band exhibits the highest energy, while highfrequency components remain relatively flat. These findings provide an important basis for a deeper understanding of transformer PD characteristics and ensuring the safe and stable operation of power systems.

Electric Power Research Institute (US), State Grid Corporation of China (China) (CN), Economic Research Institute (BG), Economic Research Institute (KZ)
Affordable and clean energy
Openalex Percentile: Top 73%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines