A Joint Localization Method Using Multi-Physical Signals for Partial Discharges in Transformer Oil

Partial discharge (PD) in transformer oil indicates insulation deterioration, requiring accurate detection for power system security. To overcome limitations of single-signal methods, this work proposes a transformer PD monitoring approach using electrical-acoustic signal fusion. Finite element simulations reveal PD-generated <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mu \mathrm{s}$</tex>-level electrical pulses and dielectric-modulated acoustic waves with spherical attenuation. Discharge sources are localized in 3D via TDOA algorithm with multi-sensor collaboration, achieving precision within transformer structural limits. Simulations confirm the fused-signal method enhances anti-interference capability and localization reliability, offering an effective solution for intelligent power equipment monitoring with theoretical and practical value.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icempe66159.2025.11123080
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Joint Localization Method Using Multi-Physical Signals for Partial Discharges in Transformer Oil

Jingyuan Chi, Bing Wei, Song Cheng, Mingze Zhang et al.
Power Transformer Diagnostics and Insulation
article

A Joint Localization Method Using Multi-Physical Signals for Partial Discharges in Transformer Oil

Jingyuan Chi, Bing Wei, Song Cheng, Mingze Zhang, Liang Zhang, Yi Lü
article en

Abstract

Partial discharge (PD) in transformer oil indicates insulation deterioration, requiring accurate detection for power system security. To overcome limitations of single-signal methods, this work proposes a transformer PD monitoring approach using electrical-acoustic signal fusion. Finite element simulations reveal PD-generated <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mu \mathrm{s}$</tex>-level electrical pulses and dielectric-modulated acoustic waves with spherical attenuation. Discharge sources are localized in 3D via TDOA algorithm with multi-sensor collaboration, achieving precision within transformer structural limits. Simulations confirm the fused-signal method enhances anti-interference capability and localization reliability, offering an effective solution for intelligent power equipment monitoring with theoretical and practical value.

Heilongjiang University of Science and Technology (CN), Electric Power Research Institute (US), Harbin Electric Corporation (China) (CN), Heilongjiang Electric Power Workers University (CN)
Affordable and clean energy
Openalex Percentile: Top 79%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Joint Localization Method Using Multi-Physical Signals for Partial Discharges in Transformer Oil — Jingyuan Chi, Bing Wei, et al. · (2025) | TGRS Research Map | TGRS