Simulation on Bending Characteristics of Spiral-Structured Profile Conductor Cable

With the increasing demand for electricity and the accelerated construction of power grids, traditional circular compacted conductor cable, due to the monofilament gaps, result in larger cross-sections, which limits its application. By optimizing the conductor structure and adopting fan-shaped, Z-shaped and other types of profiled stranding technology, the profile cable realizes the effect of energy saving and consumption reduction. To investigate the mechanical properties and structural characteristics of profiled conductor during the processes of being wound onto the cable drum, unwound from the cable drum, and routine laying. We established a threedimensional helical structure simulation model of profiled conductor, analyzed the bending stress distribution and wire compactness of profiled conductor under different pitches, compaction coefficients and aspect ratio. We also compared with circular compacted conductor. The aim is to provide theoretical basis and technical support for manufacturers in optimizing conductor structures. The results indicated that the pitch of the profiled conductor should be moderate, and the length should be controlled at about 20 times of the conductor diameter; The compaction coefficient significantly influences the bending performance, and the different gap sizes between monofilament will lead to regular changes in stress; When the aspect ratio of the monofilament is about 1.4, the stress distribution of the conductor is uniform and the monofilament is compact; The bending stress of the profiled conductor is lower than that of the circular compacted conductor, however, in terms of the tightness of the monofilament, the profile conductor is not as good as the circular compacted conductor.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icempe66159.2025.11123077
Primary Topic
Mechanical stress and fatigue analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation on Bending Characteristics of Spiral-Structured Profile Conductor Cable

Hong Yu Zhang, Chang‐Yi Wu, Chen Wu, Jinghui Gao
Mechanical stress and fatigue analysis
article

Simulation on Bending Characteristics of Spiral-Structured Profile Conductor Cable

Hong Yu Zhang, Chang‐Yi Wu, Chen Wu, Jinghui Gao
article en

Abstract

With the increasing demand for electricity and the accelerated construction of power grids, traditional circular compacted conductor cable, due to the monofilament gaps, result in larger cross-sections, which limits its application. By optimizing the conductor structure and adopting fan-shaped, Z-shaped and other types of profiled stranding technology, the profile cable realizes the effect of energy saving and consumption reduction. To investigate the mechanical properties and structural characteristics of profiled conductor during the processes of being wound onto the cable drum, unwound from the cable drum, and routine laying. We established a threedimensional helical structure simulation model of profiled conductor, analyzed the bending stress distribution and wire compactness of profiled conductor under different pitches, compaction coefficients and aspect ratio. We also compared with circular compacted conductor. The aim is to provide theoretical basis and technical support for manufacturers in optimizing conductor structures. The results indicated that the pitch of the profiled conductor should be moderate, and the length should be controlled at about 20 times of the conductor diameter; The compaction coefficient significantly influences the bending performance, and the different gap sizes between monofilament will lead to regular changes in stress; When the aspect ratio of the monofilament is about 1.4, the stress distribution of the conductor is uniform and the monofilament is compact; The bending stress of the profiled conductor is lower than that of the circular compacted conductor, however, in terms of the tightness of the monofilament, the profile conductor is not as good as the circular compacted conductor.

Intelligent Health (United Kingdom) (GB), State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
Sustainable cities and communities
Openalex Percentile: Top 75%
Mechanical stress and fatigue analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.