Integrated Podiatric Measurement System for Anthropometric Angle Analysis and Plantar Load Distribution

To address the needs of orthopedists in classifying foot pathologies affecting the forefoot, midfoot, and rearfoot, this study proposes an integrated system for simultaneously measuring anthropometric angles and plantar load distribution. Special attention is given to the method for calculating the tibiocalcaneal angle. A representative sample of 20 measurements was selected from a larger experiment involving 100 subjects. These measurements were compared with manually obtained values using KINOVEA software. The analysis, based on standard deviation and root mean square error, demonstrated high reliability of the proposed system, supporting its precision for clinical and research applications.

Authors

Institutions

Publication Details

Published
2025-06-20
DOI
https://doi.org/10.1109/isie62713.2025.11124644
Primary Topic
Ergonomics and Musculoskeletal Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated Podiatric Measurement System for Anthropometric Angle Analysis and Plantar Load Distribution

Gabriel Trujillo‐Hernández, Julio Cesar Rodriguez-Quinonez, Oleg Sergiyenko, Moises Jesus Castro-Toscano et al.
Ergonomics and Musculoskeletal Disorders
article

Integrated Podiatric Measurement System for Anthropometric Angle Analysis and Plantar Load Distribution

Gabriel Trujillo‐Hernández, Julio Cesar Rodriguez-Quinonez, Oleg Sergiyenko, Moises Jesus Castro-Toscano, Wendy Flores‐Fuentes, Dayanna Ortiz‐Villaseñor, Marla Sandoval-Jimenez
article en

Abstract

To address the needs of orthopedists in classifying foot pathologies affecting the forefoot, midfoot, and rearfoot, this study proposes an integrated system for simultaneously measuring anthropometric angles and plantar load distribution. Special attention is given to the method for calculating the tibiocalcaneal angle. A representative sample of 20 measurements was selected from a larger experiment involving 100 subjects. These measurements were compared with manually obtained values using KINOVEA software. The analysis, based on standard deviation and root mean square error, demonstrated high reliability of the proposed system, supporting its precision for clinical and research applications.

Mexicali Institute of Technology (MX)
Openalex Percentile: Top 74%
Ergonomics and Musculoskeletal Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.