A Semi-Physical Simulation System for Evaluation of Cardiopulmonary Resuscitation Mechanical Compression Parameters Based on Fracture Risk and Blood Perfusion

High-quality cardiopulmonary resuscitation (CPR) is a critical determinant of survival following cardiac arrest. In recent years, mechanical compression has become increasingly prevalent in the emergency management of cardiac arrest. The settings of key compression parameters strongly influence the effectiveness of chest compression. This study developed a semi-physical simulation platform and evaluation criteria to assess the optimal parameters for CPR. A multi-spring system was designed to simulate the risk of sternal fractures during chest compression. Additionally, a blood flow model was constructed to simulate blood perfusion. The evaluation criteria, which include quantifying sternal fracture risk and blood perfusion, are used to calculate the compression effect by inputting the compression force and depth data into the evaluation model. (Analysis of Variance)ANOVA analysis demonstrated statistically significant impacts of different compression parameters on compression outcomes. The results demonstrated that the mechanical waveform data more accurately reflected the compression dynamics encountered in real-world CPR circumstances. The trapezoidal compression waveform demonstrated clear superiority over triangle and sine waveforms, enhancing blood circulation. This study’s exploration of the trapezoidal waveform fills a gap in the AHA guidelines. In addition to the waveform, the study confirmed that a compression depth of 50 mm and a frequency of 120 compressions per minute yielded the most effective hemodynamic outcomes. These findings validated and expanded upon the AHA guidelines, offering a novel and comprehensive approach to optimising CPR effectiveness, improving both patient survival rates and the quality of mechanical resuscitation.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-08-25
DOI
https://doi.org/10.1109/jsen.2025.3589561
Primary Topic
Cardiac Arrest and Resuscitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Semi-Physical Simulation System for Evaluation of Cardiopulmonary Resuscitation Mechanical Compression Parameters Based on Fracture Risk and Blood Perfusion

Peng Zhao, Jiefeng Xu, Yifeng Pan, Yufeng Hu et al.
IEEE Sensors Journal
Cardiac Arrest and Resuscitation
article

A Semi-Physical Simulation System for Evaluation of Cardiopulmonary Resuscitation Mechanical Compression Parameters Based on Fracture Risk and Blood Perfusion

Peng Zhao, Jiefeng Xu, Yifeng Pan, Yufeng Hu, Mao Zhang, Y. Chen
article en

Abstract

High-quality cardiopulmonary resuscitation (CPR) is a critical determinant of survival following cardiac arrest. In recent years, mechanical compression has become increasingly prevalent in the emergency management of cardiac arrest. The settings of key compression parameters strongly influence the effectiveness of chest compression. This study developed a semi-physical simulation platform and evaluation criteria to assess the optimal parameters for CPR. A multi-spring system was designed to simulate the risk of sternal fractures during chest compression. Additionally, a blood flow model was constructed to simulate blood perfusion. The evaluation criteria, which include quantifying sternal fracture risk and blood perfusion, are used to calculate the compression effect by inputting the compression force and depth data into the evaluation model. (Analysis of Variance)ANOVA analysis demonstrated statistically significant impacts of different compression parameters on compression outcomes. The results demonstrated that the mechanical waveform data more accurately reflected the compression dynamics encountered in real-world CPR circumstances. The trapezoidal compression waveform demonstrated clear superiority over triangle and sine waveforms, enhancing blood circulation. This study’s exploration of the trapezoidal waveform fills a gap in the AHA guidelines. In addition to the waveform, the study confirmed that a compression depth of 50 mm and a frequency of 120 compressions per minute yielded the most effective hemodynamic outcomes. These findings validated and expanded upon the AHA guidelines, offering a novel and comprehensive approach to optimising CPR effectiveness, improving both patient survival rates and the quality of mechanical resuscitation.

IEEE Sensors JournalVol. 25(17)
Second Affiliated Hospital of Zhejiang University (CN), Zhejiang University (CN)
National Key Research and Development Program of China
Good health and well-being
Openalex Percentile: Top 67%
Cardiac Arrest and Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.