An Improved RF Dielectric Sensor for Real-Time Noninvasive Moisture Measurement of In Situ Corn Kernels

Noninvasive moisture monitoring of corn ears is critical for precision agriculture and mechanized harvesting applications. This paper presents an improved RF dielectric sensor utilizing fringe-field differential detection for continuous non-destructive corn ear kernel moisture monitoring. The initial sensor design exhibited measurement error of 8.2% at the 95% confidence level due to non-uniform axial moisture distribution within kernels and interference from high-moisture corn husks affecting the effective measurement depth of the electrodes. Through systematic optimization of sensor probe structure and measurement circuitry, including expanding the wide electrode measurement depth coverage from 28% to 57% of the kernel layer and refining the circuit calibration methodology, the measurement error was successfully reduced from 8.2% to 4.2% at the 95% confidence level. Field validation conducted on five in situ corn ears over a 20-day period confirmed the enhanced performance of the proposed sensor for agricultural instrumentation applications.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3602535
Primary Topic
Soil Moisture and Remote Sensing
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Improved RF Dielectric Sensor for Real-Time Noninvasive Moisture Measurement of In Situ Corn Kernels

Lan Huang, Yang Xiang, Hai-Ying Zheng, Lifeng Fan et al.
1 links
IEEE Transactions on Instrumentation and Measurement
Soil Moisture and Remote Sensing
article

An Improved RF Dielectric Sensor for Real-Time Noninvasive Moisture Measurement of In Situ Corn Kernels

Lan Huang, Yang Xiang, Hai-Ying Zheng, Lifeng Fan, Liu-Deng Zhang, Aowen Wang, Zhongyi Wang, Y. J. Lin, K. Xia
article en

Abstract

Noninvasive moisture monitoring of corn ears is critical for precision agriculture and mechanized harvesting applications. This paper presents an improved RF dielectric sensor utilizing fringe-field differential detection for continuous non-destructive corn ear kernel moisture monitoring. The initial sensor design exhibited measurement error of 8.2% at the 95% confidence level due to non-uniform axial moisture distribution within kernels and interference from high-moisture corn husks affecting the effective measurement depth of the electrodes. Through systematic optimization of sensor probe structure and measurement circuitry, including expanding the wide electrode measurement depth coverage from 28% to 57% of the kernel layer and refining the circuit calibration methodology, the measurement error was successfully reduced from 8.2% to 4.2% at the 95% confidence level. Field validation conducted on five in situ corn ears over a 20-day period confirmed the enhanced performance of the proposed sensor for agricultural instrumentation applications.

IEEE Transactions on Instrumentation and MeasurementVol. 74
China Agricultural University (CN)
National Natural Science Foundation of China
Zero hunger
Openalex Percentile: Top 80%
Soil Moisture and Remote Sensing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Improved RF Dielectric Sensor for Real-Time Noninvasive Moisture Measurement of In Situ Corn Kernels — Lan Huang, Yang Xiang, et al. · IEEE Transactions on Instrumentation and Measurement (2025) | TGRS Research Map | TGRS