Fiber-Optic Sensor With Dual Peanut-Type Pull-Cone Structure for Monitoring of Pulse and Respiration

Pulse and respiration are important physiological signals that represent the health of the cardiovascular and respiratory systems, it is necessary for the development of advanced monitoring technology. In paper, a wearable fiber-optic sensor for pulse and respiration monitoring is proposed. The sensor has a double peanut-type pull-cone structure, and mainly consists of a section of middle-tapered multimode fiber (MMF) which is sandwiched by two sections of single-mode fibers (SMFs). Since the fused points between the SMF and MMF are respectively fabricated to peanut shapes, the multimode interference can be induced. The experiment results demonstrate that the intensity of sensor’s spectral interference peak is sensitive to bending, but not to temperature. The curvature sensitivities are 13.803 dB/m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> and 2.054 dB/m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> in ranges of 0~1.138 m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> and 1.138~5.915 m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>, respectively. The temperature sensitivity of the sensor is less than 0.0027 dB/°C in temperature range of 20~50 °C, which makes it mostly unaffected by ambient temperature in measurements of pulse and respiration. As the sensor is used to analyze the physiological signals of different subjects, not only the pulse-related parameters such as pulse frequency, augmentation index (AIx), waveform eigenvalue K-value and blood viscosity (V) can be obtained from the analysis of pulse waveforms successfully, but also demonstrate that the sensor can effectively distinguish different respiratory states, which expanded the functional applications of the fiber-optic sensor in biomedicine field.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-08-25
DOI
https://doi.org/10.1109/jsen.2025.3600358
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fiber-Optic Sensor With Dual Peanut-Type Pull-Cone Structure for Monitoring of Pulse and Respiration

Zhengxuan Wang, Zhe Wei, Yinggang Liu, Mei Yang et al.
2 citations
IEEE Sensors Journal
Non-Invasive Vital Sign Monitoring
1.35
article

Fiber-Optic Sensor With Dual Peanut-Type Pull-Cone Structure for Monitoring of Pulse and Respiration

Zhengxuan Wang, Zhe Wei, Yinggang Liu, Mei Yang, Zilong Liu, Jiapeng Wang
article en
2 citations

Abstract

Pulse and respiration are important physiological signals that represent the health of the cardiovascular and respiratory systems, it is necessary for the development of advanced monitoring technology. In paper, a wearable fiber-optic sensor for pulse and respiration monitoring is proposed. The sensor has a double peanut-type pull-cone structure, and mainly consists of a section of middle-tapered multimode fiber (MMF) which is sandwiched by two sections of single-mode fibers (SMFs). Since the fused points between the SMF and MMF are respectively fabricated to peanut shapes, the multimode interference can be induced. The experiment results demonstrate that the intensity of sensor’s spectral interference peak is sensitive to bending, but not to temperature. The curvature sensitivities are 13.803 dB/m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> and 2.054 dB/m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> in ranges of 0~1.138 m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> and 1.138~5.915 m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>, respectively. The temperature sensitivity of the sensor is less than 0.0027 dB/°C in temperature range of 20~50 °C, which makes it mostly unaffected by ambient temperature in measurements of pulse and respiration. As the sensor is used to analyze the physiological signals of different subjects, not only the pulse-related parameters such as pulse frequency, augmentation index (AIx), waveform eigenvalue K-value and blood viscosity (V) can be obtained from the analysis of pulse waveforms successfully, but also demonstrate that the sensor can effectively distinguish different respiratory states, which expanded the functional applications of the fiber-optic sensor in biomedicine field.

IEEE Sensors JournalVol. 25(19)
Xi'an Shiyou University (CN)
Zero hunger
Openalex Percentile: Top 18%
Non-Invasive Vital Sign Monitoring
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.