Simultaneous Multiwavelength Illumination for Thermoreflectance Sensitivity Enhancement

ThermoReflectance (TR) sensitivity is inherently limited by the material-dependent TR coefficient (<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">C</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><i>TR</i></sub>), which varies with wavelength. This paper presents a novel approach to enhancing TR sensitivity by illuminating the inspected surface of the device under test with non-coherent light at multiple wavelengths simultaneously. By leveraging the superposition principle, the proposed method extracts an effective <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">C</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><i>TR</i></sub> from the combined wavelengths, using a simpler setup than mainstream approaches. A mathematical analysis investigates the influence of initial thermal conditions and camera multi-wavelength detection on temperature measurements, as well as the approach’s feasibility. Experimental assessment using a thermal test chip demonstrates that the multi-wavelength illumination strategy (at 430 and 546 nm) enhances in average, TR sensitivity by up to 280% compared to the single-wavelength one (at 546 nm). Consequently, the proposed solution achieves a TR accuracy of 4%, improves the signal-to-noise ratio by 11%, and the measurement time is halved compared to single-wavelength based mainstream strategies. Thus, this approach enables dynamic thermal measurements in microelectronics and other application fields requiring high lateral resolution.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3602567
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Multiwavelength Illumination for Thermoreflectance Sensitivity Enhancement

X. Perpiñà, X. Jordà, R. Del Sole
5 links
IEEE Transactions on Instrumentation and Measurement
Calibration and Measurement Techniques
article

Simultaneous Multiwavelength Illumination for Thermoreflectance Sensitivity Enhancement

X. Perpiñà, X. Jordà, R. Del Sole
article en

Abstract

ThermoReflectance (TR) sensitivity is inherently limited by the material-dependent TR coefficient (<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">C</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><i>TR</i></sub>), which varies with wavelength. This paper presents a novel approach to enhancing TR sensitivity by illuminating the inspected surface of the device under test with non-coherent light at multiple wavelengths simultaneously. By leveraging the superposition principle, the proposed method extracts an effective <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">C</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><i>TR</i></sub> from the combined wavelengths, using a simpler setup than mainstream approaches. A mathematical analysis investigates the influence of initial thermal conditions and camera multi-wavelength detection on temperature measurements, as well as the approach’s feasibility. Experimental assessment using a thermal test chip demonstrates that the multi-wavelength illumination strategy (at 430 and 546 nm) enhances in average, TR sensitivity by up to 280% compared to the single-wavelength one (at 546 nm). Consequently, the proposed solution achieves a TR accuracy of 4%, improves the signal-to-noise ratio by 11%, and the measurement time is halved compared to single-wavelength based mainstream strategies. Thus, this approach enables dynamic thermal measurements in microelectronics and other application fields requiring high lateral resolution.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Institut de Microelectrònica de Barcelona (ES)
Agència de Gestió d'Ajuts Universitaris i de Recerca
Openalex Percentile: Top 70%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simultaneous Multiwavelength Illumination for Thermoreflectance Sensitivity Enhancement — X. Perpiñà, X. Jordà, et al. · IEEE Transactions on Instrumentation and Measurement (2025) | TGRS Research Map | TGRS