Cataract Surgery in Pseudoexfoliation Syndrome Using the Eight-Chop Technique

<b>Objectives:</b> This study aimed to evaluate the safety and efficacy of the eight-chop technique in cataract surgery in patients with pseudoexfoliation (PEX) syndrome and assess the intraoperative parameters, changes in corneal endothelial cells, intraocular pressure (IOP), and intraoperative complications. <b>Methods:</b> This technique was applied in patients with and without PEX syndrome. Preoperative and postoperative assessments were conducted on best-corrected visual acuity, IOP, corneal endothelial cell density (CECD), coefficient of variation, percentage of hexagonal cells, and central corneal thickness. Intraoperative recordings included operative time, phaco time, aspiration time, cumulative dissipated energy (CDE), and fluid of volume used. <b>Results:</b> We analyzed 150 eyes from 150 patients (mean age, 75.5 ± 5.7 years; 59 men, 91 women). In the PEX group, operative time, phaco time, aspiration time, CDE, and volume of fluid used were 6.7 min, 17.4 s, 85.2 s, 6.91 µJ, and 33.4 mL, respectively, demonstrating favorable surgical metrics. On the other hand, in the control group, operative time, phaco time, aspiration time, CDE, and volume of fluid used were 4.5 min, 14.3 s, 64.0 s, 5.83 µJ, and 25.5 mL, respectively. In addition, CECD losses were 3.7% at week 7 and 2.7% at week 19 in the PEX group and 2.7% and 1.6%, respectively, in the control group. Significant decreases were observed at 7 and 19 weeks postoperatively in the PEX and control groups. No eye in the PEX group required a capsular tension ring due to zonular dialysis. <b>Conclusions:</b> The eight-chop technique in cataract surgery demonstrates excellent intraoperative parameters in patients with PEX, is effective against zonular weakness, and does not require the use of a capsular tension ring. This technique will aid in establishing personalized treatment strategies and improve cataract management and treatment.

Authors

Institutions

Publication Details

Journal
Journal of Personalized Medicine
Published
2025-08-25
DOI
https://doi.org/10.3390/jpm15090396
Citations
2
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
3.41
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cataract Surgery in Pseudoexfoliation Syndrome Using the Eight-Chop Technique

Tsuyoshi Sato
2 citations
Journal of Personalized Medicine
Glaucoma and retinal disorders
3.41
article

Cataract Surgery in Pseudoexfoliation Syndrome Using the Eight-Chop Technique

Tsuyoshi Sato
article en
2 citations

Abstract

<b>Objectives:</b> This study aimed to evaluate the safety and efficacy of the eight-chop technique in cataract surgery in patients with pseudoexfoliation (PEX) syndrome and assess the intraoperative parameters, changes in corneal endothelial cells, intraocular pressure (IOP), and intraoperative complications. <b>Methods:</b> This technique was applied in patients with and without PEX syndrome. Preoperative and postoperative assessments were conducted on best-corrected visual acuity, IOP, corneal endothelial cell density (CECD), coefficient of variation, percentage of hexagonal cells, and central corneal thickness. Intraoperative recordings included operative time, phaco time, aspiration time, cumulative dissipated energy (CDE), and fluid of volume used. <b>Results:</b> We analyzed 150 eyes from 150 patients (mean age, 75.5 ± 5.7 years; 59 men, 91 women). In the PEX group, operative time, phaco time, aspiration time, CDE, and volume of fluid used were 6.7 min, 17.4 s, 85.2 s, 6.91 µJ, and 33.4 mL, respectively, demonstrating favorable surgical metrics. On the other hand, in the control group, operative time, phaco time, aspiration time, CDE, and volume of fluid used were 4.5 min, 14.3 s, 64.0 s, 5.83 µJ, and 25.5 mL, respectively. In addition, CECD losses were 3.7% at week 7 and 2.7% at week 19 in the PEX group and 2.7% and 1.6%, respectively, in the control group. Significant decreases were observed at 7 and 19 weeks postoperatively in the PEX and control groups. No eye in the PEX group required a capsular tension ring due to zonular dialysis. <b>Conclusions:</b> The eight-chop technique in cataract surgery demonstrates excellent intraoperative parameters in patients with PEX, is effective against zonular weakness, and does not require the use of a capsular tension ring. This technique will aid in establishing personalized treatment strategies and improve cataract management and treatment.

Journal of Personalized MedicineVol. 15(9)
Satou Hospital (JP)
Openalex Percentile: Top 7%
Glaucoma and retinal disorders
3.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.