Synchronized SVPWM Scheme with Optimized Overmodulation for Three-Level NPC Inverters with Low Switching Frequency

Three-level Neutral-Point-Clamped (NPC) voltage source inverters (VSIs) have been widely used in application of medium-voltage high-power induction motor drives. Due to the limitation of a switching frequency of several hundred Hz in the high-power drive application, a 4-segment synchronized SVPWM scheme is adopted to reduce output current ripple. However, in the overmodulation region, the 4-segment synchronized SVPWM scheme shows high computation complexity and high current THD. Thus, this paper presents an optimized 4-segment synchronized overmodulation scheme with the advantages of low current harmonics and simple digital realization. Optimized and conventional 4-segment synchronized SVPWM schemes are compared and verified in experimental tests. Experimental results prove the proposed scheme can achieve lower current harmonics and computational burden in the overmodulation region, compared with traditional schemes.

Institutions

Publication Details

Journal
CSEE Journal of Power and Energy Systems
Published
2025-01-01
DOI
https://doi.org/10.17775/cseejpes.2021.03450
Citations
2
Primary Topic
Advanced Data Storage Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synchronized SVPWM Scheme with Optimized Overmodulation for Three-Level NPC Inverters with Low Switching Frequency

2 citations
CSEE Journal of Power and Energy Systems
Advanced Data Storage Technologies
article

Synchronized SVPWM Scheme with Optimized Overmodulation for Three-Level NPC Inverters with Low Switching Frequency

article en
2 citations

Abstract

Three-level Neutral-Point-Clamped (NPC) voltage source inverters (VSIs) have been widely used in application of medium-voltage high-power induction motor drives. Due to the limitation of a switching frequency of several hundred Hz in the high-power drive application, a 4-segment synchronized SVPWM scheme is adopted to reduce output current ripple. However, in the overmodulation region, the 4-segment synchronized SVPWM scheme shows high computation complexity and high current THD. Thus, this paper presents an optimized 4-segment synchronized overmodulation scheme with the advantages of low current harmonics and simple digital realization. Optimized and conventional 4-segment synchronized SVPWM schemes are compared and verified in experimental tests. Experimental results prove the proposed scheme can achieve lower current harmonics and computational burden in the overmodulation region, compared with traditional schemes.

CSEE Journal of Power and Energy Systems
Tongji University (CN)
Affordable and clean energy
Openalex Percentile: Top 75%
Advanced Data Storage Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Synchronized SVPWM Scheme with Optimized Overmodulation for Three-Level NPC Inverters with Low Switching Frequency · CSEE Journal of Power and Energy Systems (2025) | TGRS Research Map | TGRS