Improved Mathematical Model for a Single-Ground Arcing Fault in Medium Voltage Distribution Networks

Medium voltage distribution networks usually suffer from single-ground arcing fault, especially high impedance arcing fault. Moreover, induced intermittent arcing faults can severely endanger the reliability and safety of power systems. The arc model is important for high impedance arcing fault suppression and detection to effectively eliminate the single-ground arcing fault. This paper proposes an improved arc model, which is concise and explicit, based on a single-ground arcing fault conducted on a 10 kV experimental platform under different fault conditions. Characteristic parameters of single-ground arcing faults are obtained based on test results. Furthermore, characteristic parameters under different fault conditions of the improved arc model are presented. Finally, verification of the improved arc model is supported by PSCAD-EMTDC. Comparisons of the proposed arc model between three typical black-box arc models indicate that the proposed model has better performance and higher accuracy than that of the three typical arc models as fault resistance is in a range of 0.1 kΩ to 2.4 kΩ. Thus, its accuracy is acceptable and it is helpful to the simulation and suppression of arc fault overvoltage.

Institutions

Publication Details

Journal
CSEE Journal of Power and Energy Systems
Published
2025-01-01
DOI
https://doi.org/10.17775/cseejpes.2021.05120
Citations
4
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Mathematical Model for a Single-Ground Arcing Fault in Medium Voltage Distribution Networks

4 citations
CSEE Journal of Power and Energy Systems
Power Systems Fault Detection
1.21
article

Improved Mathematical Model for a Single-Ground Arcing Fault in Medium Voltage Distribution Networks

article en
4 citations

Abstract

Medium voltage distribution networks usually suffer from single-ground arcing fault, especially high impedance arcing fault. Moreover, induced intermittent arcing faults can severely endanger the reliability and safety of power systems. The arc model is important for high impedance arcing fault suppression and detection to effectively eliminate the single-ground arcing fault. This paper proposes an improved arc model, which is concise and explicit, based on a single-ground arcing fault conducted on a 10 kV experimental platform under different fault conditions. Characteristic parameters of single-ground arcing faults are obtained based on test results. Furthermore, characteristic parameters under different fault conditions of the improved arc model are presented. Finally, verification of the improved arc model is supported by PSCAD-EMTDC. Comparisons of the proposed arc model between three typical black-box arc models indicate that the proposed model has better performance and higher accuracy than that of the three typical arc models as fault resistance is in a range of 0.1 kΩ to 2.4 kΩ. Thus, its accuracy is acceptable and it is helpful to the simulation and suppression of arc fault overvoltage.

CSEE Journal of Power and Energy Systems
Chongqing University (CN), China Southern Power Grid (China) (CN)
Openalex Percentile: Top 18%
Power Systems Fault Detection
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.