Protection for HVDC Transmission Lines Based on Current Ratio of DC Filter and Smoothing Reactor

A new line protection for HVDC systems using the ratio of currents of a DC filter and smoothing reactor is presented. Characteristic analysis on a DC filter shows that it behaves like an inductor at a high frequency band whose inductance is far less than the sum of smoothing reactor inductance plus converter equivalent inductance. Based on this characteristic, fault analysis shows that during high-frequency DC line faults (on either side), the DC filter current amplitude significantly exceeds that of the smoothing reactor, with a current ratio much greater than 1. Whereas for external faults, near faulty end, DC filter current amplitude is less than the one of a smoothing reactor and current ratio at this end is smaller than 1, while the current ratio at the distance faulty end is still far greater than 1. The effectiveness of the protection is verified by a large number of simulation experiments. It does not need synchronization of signals at both ends. In addition, it has high sensitivity for high-resistance faults, and is insensitive to the length of DC transmission line and power flow change.

Institutions

Publication Details

Journal
CSEE Journal of Power and Energy Systems
Published
2025-01-01
DOI
https://doi.org/10.17775/cseejpes.2021.02330
Citations
2
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Protection for HVDC Transmission Lines Based on Current Ratio of DC Filter and Smoothing Reactor

2 citations
CSEE Journal of Power and Energy Systems
High-Voltage Power Transmission Systems
0.73
article

Protection for HVDC Transmission Lines Based on Current Ratio of DC Filter and Smoothing Reactor

article en
2 citations

Abstract

A new line protection for HVDC systems using the ratio of currents of a DC filter and smoothing reactor is presented. Characteristic analysis on a DC filter shows that it behaves like an inductor at a high frequency band whose inductance is far less than the sum of smoothing reactor inductance plus converter equivalent inductance. Based on this characteristic, fault analysis shows that during high-frequency DC line faults (on either side), the DC filter current amplitude significantly exceeds that of the smoothing reactor, with a current ratio much greater than 1. Whereas for external faults, near faulty end, DC filter current amplitude is less than the one of a smoothing reactor and current ratio at this end is smaller than 1, while the current ratio at the distance faulty end is still far greater than 1. The effectiveness of the protection is verified by a large number of simulation experiments. It does not need synchronization of signals at both ends. In addition, it has high sensitivity for high-resistance faults, and is insensitive to the length of DC transmission line and power flow change.

CSEE Journal of Power and Energy Systems
Tianjin University (CN), Beijing Jiaotong University (CN), Tsinghua University (CN)
Affordable and clean energy
Openalex Percentile: Top 24%
High-Voltage Power Transmission Systems
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Protection for HVDC Transmission Lines Based on Current Ratio of DC Filter and Smoothing Reactor · CSEE Journal of Power and Energy Systems (2025) | TGRS Research Map | TGRS