Determination of Optimal Options for Connecting and Combining Compensating Devices in an Electrical Network with a Voltage of 0.38 kV

The results of experimental studies of various options for connecting technical means for limiting current in the neutral wire to the physical model of a 0.38-kV network are presented. During the study, both the places of connection of technical means to the network and various combinations of their connection to the network model varied. A transformer with a “star/double zigzag with zero wire” winding connection scheme, a “star with zero wire/triangle” transformer group and an inductive coil were considered as technical means. Based on the experimental results, conclusions were drawn about the most rational switching location and the combination of technical means in the 0.38 kV network at asymmetric and nonlinear load.

Authors

Institutions

Publication Details

Journal
Russian Electrical Engineering
Published
2025-04-01
DOI
https://doi.org/10.3103/s1068371225700403
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Optimal Options for Connecting and Combining Compensating Devices in an Electrical Network with a Voltage of 0.38 kV

K. M. Yundin, M. A. Yundin, A. M. Isupova
Russian Electrical Engineering
Electric Power Systems and Control
article

Determination of Optimal Options for Connecting and Combining Compensating Devices in an Electrical Network with a Voltage of 0.38 kV

K. M. Yundin, M. A. Yundin, A. M. Isupova
article en

Abstract

The results of experimental studies of various options for connecting technical means for limiting current in the neutral wire to the physical model of a 0.38-kV network are presented. During the study, both the places of connection of technical means to the network and various combinations of their connection to the network model varied. A transformer with a “star/double zigzag with zero wire” winding connection scheme, a “star with zero wire/triangle” transformer group and an inductive coil were considered as technical means. Based on the experimental results, conclusions were drawn about the most rational switching location and the combination of technical means in the 0.38 kV network at asymmetric and nonlinear load.

Russian Electrical EngineeringVol. 96(4)
Stavropol State Agrarian University (RU), Don State Technical University (RU), Don State Agrarian University (RU)
Affordable and clean energy
Openalex Percentile: Top 79%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of Optimal Options for Connecting and Combining Compensating Devices in an Electrical Network with a Voltage of 0.38 kV — K. M. Yundin, M. A. Yundin, et al. · Russian Electrical Engineering (2025) | TGRS Research Map | TGRS