Design and evaluation of sportswear integrated with electrical muscle stimulation

Electrical muscle stimulation (EMS) technology integrated into sportswear offers promising potential for enhanced muscle building. However, there is limited understanding of strategic electrical parameters essential to maximize effectiveness. Therefore, this study aimed to design and develop an EMS-integrated sportswear capable of delivering targeted stimulation, and to evaluate its effectiveness through surface electromyography (sEMG) experiments. The root mean square (RMS) values of sEMG signals were analyzed, and a two-way repeated measure analysis of variance (ANOVA) with Tukey post hoc test was employed to examine the effects of varying electrical stimulation on muscle activation in the gastrocnemius, rectus femoris, and biceps femoris over nine time points ( t 1 to t 9 ). The findings indicated that the activation patterns varied across different muscle groups in response to changes in frequency, voltage, and duration of stimulation. Notably, higher frequencies (70 and 100 Hz) significantly enhanced muscle activation in the rectus femoris and biceps femoris at earlier stages, while the gastrocnemius muscle demonstrated limited response. At higher voltages (10.8 and 13.5 V), the rectus femoris and biceps femoris exhibited strong activation across most time points, whereas the gastrocnemius remained unresponsive. Conversely, lower frequencies and voltages resulted in delayed activation responses. Perceived exertion increased over time across all conditions. In addition, tactile feedback was observed earlier at higher voltages (400 seconds at 13.5 V) and higher frequencies (200 seconds at 100 Hz), indicating faster neural responses at these levels. These findings provide critical insights for optimizing EMS-integrated sportswear designs, enhancing their practical application in sports performance enhancement and rehabilitative healthcare.

Authors

Institutions

Publication Details

Journal
Textile Research Journal
Published
2025-08-25
DOI
https://doi.org/10.1177/00405175251350964
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and evaluation of sportswear integrated with electrical muscle stimulation

Joanne Y. W. Yip, Qian Zhang, Chi Wai Kan, Xiaolu Li
Textile Research Journal
Muscle activation and electromyography studies
article

Design and evaluation of sportswear integrated with electrical muscle stimulation

Joanne Y. W. Yip, Qian Zhang, Chi Wai Kan, Xiaolu Li
article en

Abstract

Electrical muscle stimulation (EMS) technology integrated into sportswear offers promising potential for enhanced muscle building. However, there is limited understanding of strategic electrical parameters essential to maximize effectiveness. Therefore, this study aimed to design and develop an EMS-integrated sportswear capable of delivering targeted stimulation, and to evaluate its effectiveness through surface electromyography (sEMG) experiments. The root mean square (RMS) values of sEMG signals were analyzed, and a two-way repeated measure analysis of variance (ANOVA) with Tukey post hoc test was employed to examine the effects of varying electrical stimulation on muscle activation in the gastrocnemius, rectus femoris, and biceps femoris over nine time points ( t 1 to t 9 ). The findings indicated that the activation patterns varied across different muscle groups in response to changes in frequency, voltage, and duration of stimulation. Notably, higher frequencies (70 and 100 Hz) significantly enhanced muscle activation in the rectus femoris and biceps femoris at earlier stages, while the gastrocnemius muscle demonstrated limited response. At higher voltages (10.8 and 13.5 V), the rectus femoris and biceps femoris exhibited strong activation across most time points, whereas the gastrocnemius remained unresponsive. Conversely, lower frequencies and voltages resulted in delayed activation responses. Perceived exertion increased over time across all conditions. In addition, tactile feedback was observed earlier at higher voltages (400 seconds at 13.5 V) and higher frequencies (200 seconds at 100 Hz), indicating faster neural responses at these levels. These findings provide critical insights for optimizing EMS-integrated sportswear designs, enhancing their practical application in sports performance enhancement and rehabilitative healthcare.

Textile Research Journal
Hong Kong Polytechnic University (HK), Donghua University (CN)
Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 79%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.