Cooling-Triggered Release of Celecoxib from Implantable Alginate-Soluplus Composite Devices

Currently, on-demand treatment of pain (both chronic and acute) is primarily achieved using opioids that are delivered systemically. Unfortunately, these drugs are highly addictive; over 5 people per hour die from opioid abuse in the US alone. A safer, nonsystemic mechanism for pain relief is therefore needed. Nonsteroidal anti-inflammatory drugs (NSAIDs) have been explored for this purpose; they are nonaddictive, provide excellent pain relief, and can be delivered locally to minimize dosage and systemic side effects. However, an on-demand release method is needed to make local delivery of these drugs a viable, convenient replacement for opioids; external stimulus-triggered release from an implantable depot is one approach. Stimuli such as heat, light, ultrasound, and RF electromagnetic radiation have been used to trigger release of various drugs from implantable drug depots; however, these require energy input and complex apparatus and are thus not comparable to the ease of oral administration. We propose localized cooling as a safe, convenient stimulus. As icepacks are already widely applied to temporarily ease local pain, introducing a drug delivery mechanism switched "ON" by cooling could enable long duration, enhanced pain relief triggered by a method with which patients are already familiar. Herein, we demonstrate that cooling-triggered release of NSAIDs can be achieved by leveraging the gel-to-sol transition exhibited by physically cross-linked thermoresponsive polymer hydrogels upon cooling below their lower critical solution temperature (LCST). We demonstrate and characterize cooling-triggered release in simulated body fluid, in cell culture, in explanted tissue, and in a live animal wound model. We show that hydrogels loaded with an NSAID (Celecoxib) can be combined with a nonthermoresponsive membrane material to create implantable devices that demonstrate up to a ∼40× increase in drug release rate upon mild cooling (29 °C) and that support multiple cycles of triggered release. These results demonstrate that cooling-triggered release of therapeutics is a promising concept that could allow patients to use a familiar method (applying an icepack to pain points) to achieve enhanced pain relief.

Authors

Institutions

Publication Details

Journal
ACS Biomaterials Science & Engineering
Published
2025-08-25
DOI
https://doi.org/10.1021/acsbiomaterials.5c00867
Primary Topic
Anesthesia and Pain Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cooling-Triggered Release of Celecoxib from Implantable Alginate-Soluplus Composite Devices

Leon M. Bellan, Romario Lobban, Sarah L. Hall, Joshua T. McCune et al.
ACS Biomaterials Science & Engineering
Anesthesia and Pain Management
article

Cooling-Triggered Release of Celecoxib from Implantable Alginate-Soluplus Composite Devices

Leon M. Bellan, Romario Lobban, Sarah L. Hall, Joshua T. McCune, Md. Jashim Uddin, Michael Carroll, Craig L. Duvall, Lawrence J. Marnett, Fang Yu, Victoria Vest
article en

Abstract

Currently, on-demand treatment of pain (both chronic and acute) is primarily achieved using opioids that are delivered systemically. Unfortunately, these drugs are highly addictive; over 5 people per hour die from opioid abuse in the US alone. A safer, nonsystemic mechanism for pain relief is therefore needed. Nonsteroidal anti-inflammatory drugs (NSAIDs) have been explored for this purpose; they are nonaddictive, provide excellent pain relief, and can be delivered locally to minimize dosage and systemic side effects. However, an on-demand release method is needed to make local delivery of these drugs a viable, convenient replacement for opioids; external stimulus-triggered release from an implantable depot is one approach. Stimuli such as heat, light, ultrasound, and RF electromagnetic radiation have been used to trigger release of various drugs from implantable drug depots; however, these require energy input and complex apparatus and are thus not comparable to the ease of oral administration. We propose localized cooling as a safe, convenient stimulus. As icepacks are already widely applied to temporarily ease local pain, introducing a drug delivery mechanism switched "ON" by cooling could enable long duration, enhanced pain relief triggered by a method with which patients are already familiar. Herein, we demonstrate that cooling-triggered release of NSAIDs can be achieved by leveraging the gel-to-sol transition exhibited by physically cross-linked thermoresponsive polymer hydrogels upon cooling below their lower critical solution temperature (LCST). We demonstrate and characterize cooling-triggered release in simulated body fluid, in cell culture, in explanted tissue, and in a live animal wound model. We show that hydrogels loaded with an NSAID (Celecoxib) can be combined with a nonthermoresponsive membrane material to create implantable devices that demonstrate up to a ∼40× increase in drug release rate upon mild cooling (29 °C) and that support multiple cycles of triggered release. These results demonstrate that cooling-triggered release of therapeutics is a promising concept that could allow patients to use a familiar method (applying an icepack to pain points) to achieve enhanced pain relief.

ACS Biomaterials Science & EngineeringVol. 11(9)
Vanderbilt University (US)
York University, National Cancer Institute, National Institute of General Medical Sciences
Affordable and clean energy
Openalex Percentile: Top 64%
Anesthesia and Pain Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.