A novel peel-away sheath technique for sheathless transradial use of 8 Fr balloon guide catheter

ObjectiveTo evaluate a novel peel-away sheath technique for sheathless transradial delivery of an 8 Fr balloon guide catheter (BGC), using a 6 Fr peel-away sheath and a 6 Fr inner catheter, without requiring device exchange or dedicated inner dilators.MethodsIn this technique, a 6 Fr peel-away sheath is first inserted into the radial artery, through which a 6 Fr inner catheter and guidewire are advanced. The sheath is then peeled and removed. The preloaded 8 Fr BGC (Branchor X), coaxially mounted over the inner catheter, is subsequently advanced into the radial artery. We retrospectively analyzed 10 consecutive patients who underwent neuroendovascular procedures using this technique.ResultsThe median patient age was 80 years (interquartile range [IQR], 75-88), with 5 males (50%). The peel-away sheath technique was technically successful in all cases (100%), with the BGC successfully delivered via transradial or transulnar access, navigated to the target vessel, and the intended procedure completed without the need for access conversion or device substitution. The median navigation time was 16 min (IQR, 10-24). Balloon inflation was performed in 5 cases (50%) for proximal flow arrest during thrombectomy, distal embolic protection during carotid artery stenting, or device delivery support during aneurysm treatment. No major access-related complications occurred, and no new permanent neurological deficits were observed.ConclusionsThis peel-away sheath technique provides a safe, efficient, and reproducible method for transradial 8 Fr BGC delivery using commonly available devices, potentially expanding the feasibility of transradial access in neuroendovascular practice.

Authors

Institutions

Publication Details

Journal
Interventional Neuroradiology
Published
2025-08-25
DOI
https://doi.org/10.1177/15910199251370813
Citations
1
Primary Topic
Vascular Procedures and Complications
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel peel-away sheath technique for sheathless transradial use of 8 Fr balloon guide catheter

Takao KANESHIRO, Takashi Sasayama, Hirotoshi Hamaguchi, Naoki Kaneko et al.
1 citations
Interventional Neuroradiology
Vascular Procedures and Complications
1.52
article

A novel peel-away sheath technique for sheathless transradial use of 8 Fr balloon guide catheter

Takao KANESHIRO, Takashi Sasayama, Hirotoshi Hamaguchi, Naoki Kaneko, Nobuyuki Sakai, Taichiro Imahori, Kohkichi Hosoda, Daisuke Yamamoto, Rikuo Nishii, Hiroki Goto, Haruka Enami, Shigeru Miyake
article en
1 citations

Abstract

ObjectiveTo evaluate a novel peel-away sheath technique for sheathless transradial delivery of an 8 Fr balloon guide catheter (BGC), using a 6 Fr peel-away sheath and a 6 Fr inner catheter, without requiring device exchange or dedicated inner dilators.MethodsIn this technique, a 6 Fr peel-away sheath is first inserted into the radial artery, through which a 6 Fr inner catheter and guidewire are advanced. The sheath is then peeled and removed. The preloaded 8 Fr BGC (Branchor X), coaxially mounted over the inner catheter, is subsequently advanced into the radial artery. We retrospectively analyzed 10 consecutive patients who underwent neuroendovascular procedures using this technique.ResultsThe median patient age was 80 years (interquartile range [IQR], 75-88), with 5 males (50%). The peel-away sheath technique was technically successful in all cases (100%), with the BGC successfully delivered via transradial or transulnar access, navigated to the target vessel, and the intended procedure completed without the need for access conversion or device substitution. The median navigation time was 16 min (IQR, 10-24). Balloon inflation was performed in 5 cases (50%) for proximal flow arrest during thrombectomy, distal embolic protection during carotid artery stenting, or device delivery support during aneurysm treatment. No major access-related complications occurred, and no new permanent neurological deficits were observed.ConclusionsThis peel-away sheath technique provides a safe, efficient, and reproducible method for transradial 8 Fr BGC delivery using commonly available devices, potentially expanding the feasibility of transradial access in neuroendovascular practice.

Interventional Neuroradiology
University of California, Los Angeles (US), Shizuoka City Shimizu Hospital (JP), Tokyo-Kita Medical Center (JP), Kobe City Medical Center General Hospital (JP), Kobe University (JP)
Openalex Percentile: Top 15%
Vascular Procedures and Complications
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.