Electrochemical determination of paracetamol and chlorpheniramine  using AuNPs-rGO modified glassy carbon electrode

One of the significant durability challenges is the corrosion of reinforced concrete. A gold nanoparticle/reduced graphene oxide modified glassy carbon electrode (AuNPs-rGO-GCE) was fabricated using an electrochemical reduction method for the simultaneous determination of paracetamol (PAR) and chlorpheniramine maleate (CPM). AuNPs-rGO modified GC electrodes were prepared through direct electrochemical reduction of GO to rGO, followed by direct reduction of Au ions to Au on the rGO matrix. X-ray diffraction, scanning electron microscopy, Fourier-transform infrared spectra, Raman spectroscopy, energy dispersive X-ray spectroscopy, high-resolution transmission electron microscopy, electrochemical impedance spectroscopy, and X-ray photoelectron spectroscopy characterized the resulting AuNPs-rGO. It was found that AuNPs around 15.4 nm were highly dispersed on the rGO. The modification of GCE by AuNPs-rGO accelerates the electron transfer process and increases the conductivity of the electrode. The AuNPs-rGO modified electrode was used to simultaneously determine PAR and CPM using the square-wave anodic stripping voltammetry (SQW-ASV) method. Under suitable experimental conditions, the SQW-ASV method using AuNPs-rGO-GCE showed a wide linear range from 23.7 to 140.0 µM for PAR and from 7.5 to 54.0 µM for CPM. The limit of detection of PAR and CPM was 7.12 and 2.54 µM, respectively. The proposed SQW-ASV method was applied to analyze PAR and CPM in samples of herbal medicine simultaneously, and the results were compared with those of high-performance liquid chromatography, with no statistical difference.

Authors

Institutions

Publication Details

Journal
Journal of Electrochemical Science and Engineering
Published
2025-08-25
DOI
https://doi.org/10.5599/jese.2841
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical determination of paracetamol and chlorpheniramine  using AuNPs-rGO modified glassy carbon electrode

Trinh Ngoc Đat, Đinh Quang Khiếu, Phạm Khắc Liệu, Thi Cam Minh Dao et al.
Journal of Electrochemical Science and Engineering
Electrochemical sensors and biosensors
article

Electrochemical determination of paracetamol and chlorpheniramine  using AuNPs-rGO modified glassy carbon electrode

Trinh Ngoc Đat, Đinh Quang Khiếu, Phạm Khắc Liệu, Thi Cam Minh Dao, Nguyễn Hải Phong, Huỳnh Văn Chung, Nguyen Thi Trang Huyen, Xuân Anh Vũ Hồ, Mạnh Dũng Đoàn, Do Thi Duyen
article en

Abstract

One of the significant durability challenges is the corrosion of reinforced concrete. A gold nanoparticle/reduced graphene oxide modified glassy carbon electrode (AuNPs-rGO-GCE) was fabricated using an electrochemical reduction method for the simultaneous determination of paracetamol (PAR) and chlorpheniramine maleate (CPM). AuNPs-rGO modified GC electrodes were prepared through direct electrochemical reduction of GO to rGO, followed by direct reduction of Au ions to Au on the rGO matrix. X-ray diffraction, scanning electron microscopy, Fourier-transform infrared spectra, Raman spectroscopy, energy dispersive X-ray spectroscopy, high-resolution transmission electron microscopy, electrochemical impedance spectroscopy, and X-ray photoelectron spectroscopy characterized the resulting AuNPs-rGO. It was found that AuNPs around 15.4 nm were highly dispersed on the rGO. The modification of GCE by AuNPs-rGO accelerates the electron transfer process and increases the conductivity of the electrode. The AuNPs-rGO modified electrode was used to simultaneously determine PAR and CPM using the square-wave anodic stripping voltammetry (SQW-ASV) method. Under suitable experimental conditions, the SQW-ASV method using AuNPs-rGO-GCE showed a wide linear range from 23.7 to 140.0 µM for PAR and from 7.5 to 54.0 µM for CPM. The limit of detection of PAR and CPM was 7.12 and 2.54 µM, respectively. The proposed SQW-ASV method was applied to analyze PAR and CPM in samples of herbal medicine simultaneously, and the results were compared with those of high-performance liquid chromatography, with no statistical difference.

Journal of Electrochemical Science and EngineeringVol. 15(6)
Duy Tan University (VN), University of Da Nang (VN), Hue University (VN), Thai Nguyen University (VN), Tay Nguyen University, Vietnam Academy of Science and Technology (VN)
Bộ Giáo dục và Ðào tạo
Openalex Percentile: Top 79%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.