Impact of side stream crossflow filtration on water quality in a HVAC circuit

This study evaluates the impact of a VORTISAND® Crossflow Microsand Filter (CMF) on the water quality and operational efficiency of a cooling tower system in a large hospital building. Data was collected over 18 months, comparing periods when the filter was active versus inactive. Results demonstrated that the filter reduces turbidity, total suspended solids, and particle counts by 20%, 25-30% and 69%, respectively. The filter was effective particularly for particles >1 μm . Filtration also decreased the concentration of iron and calcium ions by 15% and 25%, indicating its effectiveness in managing particulate and scaling components. While the filter improves water quality and stabilizes system operations, it increases water consumption by 20.7 % due to backwashing. These findings highlight the potential of integrating physical filtration into cooling tower management to optimize performance and reduce chemical use, although further strategies are needed to minimize water losses. This study offered a unique opportunity to successfully shut down the CMF in a full-scale operating system with high maintenance standards and assess the actual impact of the filtration on water quality and operability of the HVAC system. • Long-term use of a side stream crossflow filtration system improves water quality • Removal of all particles improves system efficiency and mitigates fouling issues • Side stream filtration improves process stability and reduces chemical consumption • The daily filter backwash system requires large volumes of water • Increased human resources were required to operate the system without filtration

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2025-08-25
DOI
https://doi.org/10.1016/j.jobe.2025.113796
Primary Topic
Aerosol Filtration and Electrostatic Precipitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of side stream crossflow filtration on water quality in a HVAC circuit

Alain Silverwood, Émilie Bédard, Dominique Claveau-Mallet, Vaishali Ashok et al.
Journal of Building Engineering
Aerosol Filtration and Electrostatic Precipitation
article

Impact of side stream crossflow filtration on water quality in a HVAC circuit

Alain Silverwood, Émilie Bédard, Dominique Claveau-Mallet, Vaishali Ashok, Étienne Robert, Ambroise Bellamy
article en

Abstract

This study evaluates the impact of a VORTISAND® Crossflow Microsand Filter (CMF) on the water quality and operational efficiency of a cooling tower system in a large hospital building. Data was collected over 18 months, comparing periods when the filter was active versus inactive. Results demonstrated that the filter reduces turbidity, total suspended solids, and particle counts by 20%, 25-30% and 69%, respectively. The filter was effective particularly for particles >1 μm . Filtration also decreased the concentration of iron and calcium ions by 15% and 25%, indicating its effectiveness in managing particulate and scaling components. While the filter improves water quality and stabilizes system operations, it increases water consumption by 20.7 % due to backwashing. These findings highlight the potential of integrating physical filtration into cooling tower management to optimize performance and reduce chemical use, although further strategies are needed to minimize water losses. This study offered a unique opportunity to successfully shut down the CMF in a full-scale operating system with high maintenance standards and assess the actual impact of the filtration on water quality and operability of the HVAC system. • Long-term use of a side stream crossflow filtration system improves water quality • Removal of all particles improves system efficiency and mitigates fouling issues • Side stream filtration improves process stability and reduces chemical consumption • The daily filter backwash system requires large volumes of water • Increased human resources were required to operate the system without filtration

Journal of Building EngineeringVol. 112
Xylem (United States) (US), Polytechnique Montréal (CA)
Mitacs
Clean water and sanitation
Openalex Percentile: Top 79%
Aerosol Filtration and Electrostatic Precipitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.