Electrochemical Performance and Cytocompatibility of HVOF-Sprayed Cr3C2-20(Ni20Cr)-20HAp-XSi Coatings for Dental Applications

Biocompatible coatings are widely employed in dental applications to enhance the biofunctionality of metallic implants exposed to the aggressive oral environment. Among them, hydroxyapatite (HAp)-based and carbide-reinforced coatings have been explored due to their favorable mechanical and biological performance. In this study, Cr3C-20(Ni20Cr)-20HAp-XSi coatings were deposited using the high-velocity oxy-fuel (HVOF) technique. The coatings were applied onto commercially pure titanium substrates, with the silicon content varied between X = 0, 5, 10, and 20 wt%. To evaluate the coatings’ corrosion resistance, electrochemical techniques such as potentiodynamic polarization curves, linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), and open circuit potential (OCP) were employed. Artificial saliva was used as the corrosive medium at 37 °C for 168 h. The feasibility of producing carbide-HAp-Si coatings with excellent corrosion resistance and cytocompatibility via HVOF was demonstrated here, although some of the tested coatings (20 wt% Si) showed reduced electrochemical stability, attributed to faster dissolution processes and associated with a thinner coating layer, as confirmed by SEM analyses. X-ray diffraction (XRD) analyses revealed the formation of new phases in the coatings during thermal spraying, including Cr2O3 and Cr7C3. Additionally, MTT assays using 3T3-L1 fibroblasts showed no significant cytotoxic effects after 24 and 72 h of exposure to some of the coatings, confirming their biocompatibility for potential dental applications.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-08-25
DOI
https://doi.org/10.3390/app15179308
Citations
1
Primary Topic
Electrodeposition and Electroless Coatings
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Performance and Cytocompatibility of HVOF-Sprayed Cr3C2-20(Ni20Cr)-20HAp-XSi Coatings for Dental Applications

Astrid Lorena Giraldo-Betancur, O. Sotelo-Mazón, Ana Laura Islas‐Garduño, D.G. Espinosa-Arbeláez et al.
1 citations
Applied Sciences
Electrodeposition and Electroless Coatings
0.73
article

Electrochemical Performance and Cytocompatibility of HVOF-Sprayed Cr3C2-20(Ni20Cr)-20HAp-XSi Coatings for Dental Applications

Astrid Lorena Giraldo-Betancur, O. Sotelo-Mazón, Ana Laura Islas‐Garduño, D.G. Espinosa-Arbeláez, Jorge Corona‐Castuera, Carlos A. Poblano-Salas, John Henao, Víctor Manuel Zezatti Flores, Rosa Mariana Montiel‐Ruiz
article en
1 citations

Abstract

Biocompatible coatings are widely employed in dental applications to enhance the biofunctionality of metallic implants exposed to the aggressive oral environment. Among them, hydroxyapatite (HAp)-based and carbide-reinforced coatings have been explored due to their favorable mechanical and biological performance. In this study, Cr3C-20(Ni20Cr)-20HAp-XSi coatings were deposited using the high-velocity oxy-fuel (HVOF) technique. The coatings were applied onto commercially pure titanium substrates, with the silicon content varied between X = 0, 5, 10, and 20 wt%. To evaluate the coatings’ corrosion resistance, electrochemical techniques such as potentiodynamic polarization curves, linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), and open circuit potential (OCP) were employed. Artificial saliva was used as the corrosive medium at 37 °C for 168 h. The feasibility of producing carbide-HAp-Si coatings with excellent corrosion resistance and cytocompatibility via HVOF was demonstrated here, although some of the tested coatings (20 wt% Si) showed reduced electrochemical stability, attributed to faster dissolution processes and associated with a thinner coating layer, as confirmed by SEM analyses. X-ray diffraction (XRD) analyses revealed the formation of new phases in the coatings during thermal spraying, including Cr2O3 and Cr7C3. Additionally, MTT assays using 3T3-L1 fibroblasts showed no significant cytotoxic effects after 24 and 72 h of exposure to some of the coatings, confirming their biocompatibility for potential dental applications.

Applied SciencesVol. 15(17)
Mexican Social Security Institute (MX), Center for Engineering and Industrial Development (MX), Polytechnic University of Queretaro (MX), Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (MX), Universidad Autónoma del Estado de Morelos (MX)
Openalex Percentile: Top 24%
Electrodeposition and Electroless Coatings
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.