Development of Measuring Device for Non-Invasive Blood Sugar Levels Using Photodiode Sensor

Diabetes mellitus is one of the deadliest diseases faced by Indonesians. To measure blood sugar levels, the most widely used tool is an invasive tool, namely by injuring the patient's body. Techniques like this make people reluctant to measure glucose levels in their blood regularly. Therefore, this research aims to design and build a non-invasive blood sugar measuring device using a photodiode sensor. So that this tool can be used by all groups, both medical and non-medical personnel to measure blood sugar non-invasively. In this study, blood was drawn from several patients with Miletus diabetes and carried out direct blood measurements using a photodiode sensor. The results obtained from this study are that there is an error value in the voltage measurement circuit with the calculation of the resistance value to obtain the voltage value. The error value obtained is 5%, the linear regression value is 0.996. From the measurement results, it can be concluded that the photodiode sensor can be used to measure blood sugar non-invasively

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-17
DOI
https://doi.org/10.35882/ijeeemi.v2i2.228
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Measuring Device for Non-Invasive Blood Sugar Levels Using Photodiode Sensor

Bedjo Utomo, Sumber Sumber
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Analytical Chemistry and Sensors
article

Development of Measuring Device for Non-Invasive Blood Sugar Levels Using Photodiode Sensor

Bedjo Utomo, Sumber Sumber
article en

Abstract

Diabetes mellitus is one of the deadliest diseases faced by Indonesians. To measure blood sugar levels, the most widely used tool is an invasive tool, namely by injuring the patient's body. Techniques like this make people reluctant to measure glucose levels in their blood regularly. Therefore, this research aims to design and build a non-invasive blood sugar measuring device using a photodiode sensor. So that this tool can be used by all groups, both medical and non-medical personnel to measure blood sugar non-invasively. In this study, blood was drawn from several patients with Miletus diabetes and carried out direct blood measurements using a photodiode sensor. The results obtained from this study are that there is an error value in the voltage measurement circuit with the calculation of the resistance value to obtain the voltage value. The error value obtained is 5%, the linear regression value is 0.996. From the measurement results, it can be concluded that the photodiode sensor can be used to measure blood sugar non-invasively

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 2(2)
Politeknik Kesehatan Kemenkes Semarang (ID), Eskom (South Africa) (ZA)
Openalex Percentile: Top 71%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.