A Low Cost Baby Incubator Design Equipped with Vital Sign Parameters

The aim of this study was to create a compact system at a low cost in an infant incubator. Apart from stabilizing the temperature, it can also calculate the premature baby's heart rate and oxygen saturation value. The contribution of the system being built can detect the early symptoms of congenital abnormalities so that abnormalities detection becomes more practical. The temperature stability in this system uses a threshold system, where the sensor readings are compared with the set point value. Meanwhile, the SpO2 system uses a finger sensor attached to the baby's finger to detect oxygen saturation and heart rate. The signal from the sensor is processed in a signal conditioning circuit consisting of an astable circuit, filter and amplifier, LPF, and demultiplexer. Based on the results of testing and measurement, the difference produced by this tool is only 0.13 - 0.182 ° C. The biggest error in the system is 0.517%. Measurement of skin temperature was carried out on 10 respondents with an average value of 34.825 ° C. so that the difference generated from this tool is only 0.175 ° C, the difference on the Humidity parameter is 0.21%. The average BPM reading of respondent 1 was 81 beats per minute and the average SpO2 value was 97%. The average BPM reading of respondent 2 was 83 beats per minute and the average SpO2 value was 98%. You can see that the module with the Arduino control system can work automatically and is able to adjust the stability of the baby incubator according to the settings. In addition, the BPM and SpO2 systems are within tolerance so they can be used for patient measurements

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-17
DOI
https://doi.org/10.35882/ijeeemi.v3i2.203
Primary Topic
Tactile and Sensory Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Low Cost Baby Incubator Design Equipped with Vital Sign Parameters

Muslim Ali, Lamidi Lamidi, Abd Kholiq
1 links
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Tactile and Sensory Interactions
article

A Low Cost Baby Incubator Design Equipped with Vital Sign Parameters

Muslim Ali, Lamidi Lamidi, Abd Kholiq
article en

Abstract

The aim of this study was to create a compact system at a low cost in an infant incubator. Apart from stabilizing the temperature, it can also calculate the premature baby's heart rate and oxygen saturation value. The contribution of the system being built can detect the early symptoms of congenital abnormalities so that abnormalities detection becomes more practical. The temperature stability in this system uses a threshold system, where the sensor readings are compared with the set point value. Meanwhile, the SpO2 system uses a finger sensor attached to the baby's finger to detect oxygen saturation and heart rate. The signal from the sensor is processed in a signal conditioning circuit consisting of an astable circuit, filter and amplifier, LPF, and demultiplexer. Based on the results of testing and measurement, the difference produced by this tool is only 0.13 - 0.182 ° C. The biggest error in the system is 0.517%. Measurement of skin temperature was carried out on 10 respondents with an average value of 34.825 ° C. so that the difference generated from this tool is only 0.175 ° C, the difference on the Humidity parameter is 0.21%. The average BPM reading of respondent 1 was 81 beats per minute and the average SpO2 value was 97%. The average BPM reading of respondent 2 was 83 beats per minute and the average SpO2 value was 98%. You can see that the module with the Arduino control system can work automatically and is able to adjust the stability of the baby incubator according to the settings. In addition, the BPM and SpO2 systems are within tolerance so they can be used for patient measurements

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 3(2)
Politeknik Kesehatan Kementerian Kesehatan Jakarta II (ID), Politeknik Kesehatan Kemenkes Semarang (ID), Eskom (South Africa) (ZA), University of Gezira (SD)
Openalex Percentile: Top 78%
Tactile and Sensory Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.