Design a Monitoring Device for Heart-Attack Early Detection Based on Respiration Rate and Body Temperature Parameters

Acute myocardial infarction, commonly referred to as a heart attack, is the most common cause of sudden death where a monitoring tool is needed that is equipped with a system that can notify doctors to take immediate action. The purpose of this study was to design a heart attack detection device through indicators of vital human signs. The contribution of this research is that the system works in real-time, has more parameters, uses wireless, and is equipped with a system to detect indications of a heart attack. In order for wireless monitoring to be carried out in real-time and supported by a detection system, this design uses a radio frequency module as data transmission and uses a warning system that is used for detection. Respiration rate was measured using the piezoelectric sensor, and body temperature was measured using the DS18B20 temperature sensor. Processing of sensor data is done with ESP32, which is displayed wirelessly by the HC-12 module on the PC. If an indication of a heart attack is detected in the parameter value, the tool will activate a notification on the PC. In every indication of a heart attack, it was found that this design can provide notification properly. The results showed that the largest respiratory error value was 4%, and the largest body temperature error value was 0.55%. The results of this study can be implemented in patients who have been diagnosed with heart attack disease so that it can facilitate monitoring the patient's condition

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-18
DOI
https://doi.org/10.35882/ijeeemi.v3i3.244
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design a Monitoring Device for Heart-Attack Early Detection Based on Respiration Rate and Body Temperature Parameters

Hayder J. Hassaballah, I Dewa Gede Hari Wisana, Priyambada Cahya Nugraha, Isna Fatimatuz Zahra
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Non-Invasive Vital Sign Monitoring
article

Design a Monitoring Device for Heart-Attack Early Detection Based on Respiration Rate and Body Temperature Parameters

Hayder J. Hassaballah, I Dewa Gede Hari Wisana, Priyambada Cahya Nugraha, Isna Fatimatuz Zahra
article en

Abstract

Acute myocardial infarction, commonly referred to as a heart attack, is the most common cause of sudden death where a monitoring tool is needed that is equipped with a system that can notify doctors to take immediate action. The purpose of this study was to design a heart attack detection device through indicators of vital human signs. The contribution of this research is that the system works in real-time, has more parameters, uses wireless, and is equipped with a system to detect indications of a heart attack. In order for wireless monitoring to be carried out in real-time and supported by a detection system, this design uses a radio frequency module as data transmission and uses a warning system that is used for detection. Respiration rate was measured using the piezoelectric sensor, and body temperature was measured using the DS18B20 temperature sensor. Processing of sensor data is done with ESP32, which is displayed wirelessly by the HC-12 module on the PC. If an indication of a heart attack is detected in the parameter value, the tool will activate a notification on the PC. In every indication of a heart attack, it was found that this design can provide notification properly. The results showed that the largest respiratory error value was 4%, and the largest body temperature error value was 0.55%. The results of this study can be implemented in patients who have been diagnosed with heart attack disease so that it can facilitate monitoring the patient's condition

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 3(3)
Middle Technical University (IQ), Politeknik Kesehatan Kemenkes Semarang (ID), Poltekkes Kemenkes Surabaya, Eskom (South Africa) (ZA)
Openalex Percentile: Top 79%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.