Visual-based joint calibration method for multirobot systems

A vision based joint calibration method for multi robot systems is proposed to address various parameter calibration issues (hand eye, positioner, dual robot base coordinate system calibration). Firstly, the chessboard calibration board data is collected by an industrial camera, and the calibration parameters of the hand eye, displacement machine, and dual robots are calculated using linear algorithms as initial values. Then, a joint calibration objective function for the multi robot system is established, and the calibration parameters of the hand eye, displacement machine, and dual robots of the multi robot system are optimized using gradient descent algorithm. The final experiment showed that the average maximum distance between the center points optimized by this calibration method was 4.07mm, significantly better than the average maximum distance before optimization of 5.34mm. The average standard deviation of the overall data after optimization was 2.37mm, significantly better than the average standard deviation before optimization of 3.08mm, proving that this calibration optimization method improves the overall calibration accuracy of the multi robot system.

Authors

Institutions

Publication Details

Published
2025-08-15
DOI
https://doi.org/10.1117/12.3072070
Primary Topic
Advanced Vision and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visual-based joint calibration method for multirobot systems

Chengzhi Su, Shengming He, Jingran Yuan, Enguo Wang et al.
Advanced Vision and Imaging
article

Visual-based joint calibration method for multirobot systems

Chengzhi Su, Shengming He, Jingran Yuan, Enguo Wang, Ji Qi
article en

Abstract

A vision based joint calibration method for multi robot systems is proposed to address various parameter calibration issues (hand eye, positioner, dual robot base coordinate system calibration). Firstly, the chessboard calibration board data is collected by an industrial camera, and the calibration parameters of the hand eye, displacement machine, and dual robots are calculated using linear algorithms as initial values. Then, a joint calibration objective function for the multi robot system is established, and the calibration parameters of the hand eye, displacement machine, and dual robots of the multi robot system are optimized using gradient descent algorithm. The final experiment showed that the average maximum distance between the center points optimized by this calibration method was 4.07mm, significantly better than the average maximum distance before optimization of 5.34mm. The average standard deviation of the overall data after optimization was 2.37mm, significantly better than the average standard deviation before optimization of 3.08mm, proving that this calibration optimization method improves the overall calibration accuracy of the multi robot system.

Changchun University of Science and Technology (CN), Ningbo Product Quality Supervision and Inspection Institute (CN)
Openalex Percentile: Top 79%
Advanced Vision and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Visual-based joint calibration method for multirobot systems — Chengzhi Su, Shengming He, et al. · (2025) | TGRS Research Map | TGRS